Keysight (Agilent) 16803A CALIBRATION and Keysight (Agilent) 16803A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 16803A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 16803A   Description / Specification:    
Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer

The Agilent 16803A 102 channel Portable Logic Analyzer lets you make accurate high-speed timing measurements with 4 GHz (250 ps) high-speed timing zoom. A parallel acquisition architecture provides high-speed timing measurements simultaneously through the same probe used for state or timing measurements. Timing zoom stays active all the time with no tradeoffs. View data at high resolution over longer periods of time with 64-K-deep timing zoom. Specifications and Characteristics. Logic analyzer channels: 102, (98 data + 4 clocks), Unused clock channels can be used as data channels. High-speed timing zoom: 4 GHz (250 ps) with 64 K depth. Maximum timing sample rate (Half/full ch): 1.0 GHz (1.0 ns) / 500 MHz (2.0 ns). Memory depth in full channel mode: based on option installed, 1 to 32 M. Maximum trigger sequence speed: 250 MHz. Maximum trigger sequence levels: 16. Trigger sequence level branching: Arbitrary 4-way if/then/else. Trigger position: Start, center, end, or user-defined. LCD display: 38.1-cm (15-in.) display makes is easy to view a large number of waveforms or states. Options; -001, 1 M Memory depth. -004, 4 M Memory depth. -016, 16 M Memory depth. -032, 32 M Memory depth. -250, 250 MHz State speed. -500, 450 MHz State speed. -101, Internal Hard Drive. -102, Front Panel with 15” Display. -103, Front Panel with 15” Display Touch screen. -109, External removable hard drive.



 

Standard Calibration $690.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 16803A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 16803A CALIBRATION and/or Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: