Keysight (Agilent) B2901A CALIBRATION and Keysight (Agilent) B2901A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B2901A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) B2901A   Description / Specification:    
Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit

The Keysight / Agilent B2901A Single Channel Precision Source/Measure Unit is a compact and cost-effective bench-top Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. These capabilities make the B2901A ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy.
Specifications.

Voltage source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max voltage.
  ±200 mV, 1 μV, ±(0.015 % + 225 μV), ≤ 10 μV, ±210 mV.
  ±2 V, 10 μV, ±(0.02 % + 350 μV), ≤ 20 μV, ±2.1 V.
  ±20 V, 100 μV, ±(0.015 % + 5 mV), ≤ 200 μV, ±21 V.
  ±200 V, 1 mV, ±(0.015 % + 50 mV), ≤ 2 mV, ±210 V.

Current source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max current.
  ±100 nA, 1 pA, ±(0.06 % + 100 pA), ≤ 2 pA, ±105 nA.
  ±1 μA, 10 pA, ±(0.025 % + 500 pA), ≤ 25 pA, ±1.05 μA.
  ±10 μA, 100 pA, ±(0.025 % + 1.5 nA), ≤ 60 pA, ±10.5 μA.
  ±100 μA, 1 nA, ±(0.02 % + 25 nA), ≤ 2 nA, ±105 μA.
  ±1 mA, 10 nA, ±(0.02 % + 200 nA), ≤ 6 nA, ±1.05 mA.
  ±10 mA, 100 nA, ±(0.02 % + 2.5 μA), ≤ 200 nA, ±10.5 mA.
  ±100 mA, 1 μA, ±(0.02 % + 20 μA), ≤ 600 nA, ±105 mA.
  ±1 A, 10 μA, ±(0.03 % + 1.5 mA), ≤ 70 μA, ±1.05 A.
  ±1.5 A, 10 μA, ±(0.05 % + 3.5 mA), ≤ 100 μA, ±1.515 A.
  ±3 A, 100 μA, ±(0.4 % + 7 mA), ≤ 120 μA, ±3.03 A.
  ±10 A pulse mode only, 100 μA, ±(0.4 % + 25 mA), , ±10.5 A.

Maximum current limitation
  ±(0 V < V ≤ 6 V) ≤ 4 A ,
  ±(6 V < V ≤ 21 V) ≤ 2.5 A.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) B2901A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) B2901A CALIBRATION and/or Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: