Keysight (Agilent) B2901A CALIBRATION and Keysight (Agilent) B2901A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B2901A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) B2901A   Description / Specification:    
Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit

The Keysight / Agilent B2901A Single Channel Precision Source/Measure Unit is a compact and cost-effective bench-top Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. These capabilities make the B2901A ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy.
Specifications.

Voltage source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max voltage.
  ±200 mV, 1 μV, ±(0.015 % + 225 μV), ≤ 10 μV, ±210 mV.
  ±2 V, 10 μV, ±(0.02 % + 350 μV), ≤ 20 μV, ±2.1 V.
  ±20 V, 100 μV, ±(0.015 % + 5 mV), ≤ 200 μV, ±21 V.
  ±200 V, 1 mV, ±(0.015 % + 50 mV), ≤ 2 mV, ±210 V.

Current source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max current.
  ±100 nA, 1 pA, ±(0.06 % + 100 pA), ≤ 2 pA, ±105 nA.
  ±1 μA, 10 pA, ±(0.025 % + 500 pA), ≤ 25 pA, ±1.05 μA.
  ±10 μA, 100 pA, ±(0.025 % + 1.5 nA), ≤ 60 pA, ±10.5 μA.
  ±100 μA, 1 nA, ±(0.02 % + 25 nA), ≤ 2 nA, ±105 μA.
  ±1 mA, 10 nA, ±(0.02 % + 200 nA), ≤ 6 nA, ±1.05 mA.
  ±10 mA, 100 nA, ±(0.02 % + 2.5 μA), ≤ 200 nA, ±10.5 mA.
  ±100 mA, 1 μA, ±(0.02 % + 20 μA), ≤ 600 nA, ±105 mA.
  ±1 A, 10 μA, ±(0.03 % + 1.5 mA), ≤ 70 μA, ±1.05 A.
  ±1.5 A, 10 μA, ±(0.05 % + 3.5 mA), ≤ 100 μA, ±1.515 A.
  ±3 A, 100 μA, ±(0.4 % + 7 mA), ≤ 120 μA, ±3.03 A.
  ±10 A pulse mode only, 100 μA, ±(0.4 % + 25 mA), , ±10.5 A.

Maximum current limitation
  ±(0 V < V ≤ 6 V) ≤ 4 A ,
  ±(6 V < V ≤ 21 V) ≤ 2.5 A.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) B2901A CALIBRATION and/or Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: