                    The Agilent MSOX3034A X-Series’s Oscilloscope innovation starts with 5-instruments-in-1 integration. The one million waveforms per second update rate is 20 times faster than the competition to display the most signal detail. The 3000 X-Series provides maximum investment protection with fully-upgradable 5-instruments-in-1; even bandwidth is upgradable. The InfiniiVision MSOX3034A X-Series comes with a large 8.5-inch WVGA display so you can view analog, digital and serial signals easily on the screen. With up to 4 Mpts of MegaZoom IV deep memory, you can capture long, non-repeating signals while maintaining a high sample rate, then quickly zoom in on areas of interest.
 Specifications.
 
 Analog Bandwidth (- 3 dB): 350 MHz.
 Analog Input channels: 2.
 Calculated rise time (10-90%): <= 1 ns.
 
 Hardware bandwidth limits: Approximately 20 MHz (selectable).
 Input coupling: AC, DC.
 Input impedance Selectable: Selectable: 1 MΩ ± 1%; 50 Ω ± 1.5%
 Sample rate on each channel: 2 GSa/s per channel, 4 GSa/s interleaved.
 Memory depth (record length): Up to 4 Mpts.
 Display: 8.5-inch WVGA with 64 levels of intensity grading.
 Waveform update rate (max): 1,000,000 waveforms/s.
 Vertical resolution: 8 bits.
 Horizontal resolution: 2.5 ps.
 Maximum input voltage: 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk, With N2862A, N2863A or N2890A 10:1 probe: 300 Vrms.
 DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale].
 DC vertical gain accuracy: ± 2.0% full scale.
 Offset range: ±2 V (2 mV/div to 200 mV/div), ±50 V (> 200 mV/div to 5 V/div).
 DC vertical offset accuracy: ±0.1div ± 2mV ± 1% of offset setting.
 
 Vertical system digital channels.
 
 Digital input channels: 16 digital (D0 to D15).
 Thresholds: Threshold per set of 8 channels.
 Threshold selections: TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (-1.3 V), User-definable (selectable by pod).
 User-defined threshold range: ±8.0 V in 10 mV steps.
 Maximum input voltage: ±40 V peak CAT I; transient overvoltage 800 Vpk.
 Threshold accuracy: ±(100 mV + 3% of threshold setting).
 Maximum input dynamic range: ±10 V about threshold.
 Minimum voltage swing: 500 mVpp.
 
 Horizontal system analog channels.
 Maximum sample rate: 4 GSa/s half channel, 2 GSa/s all channel.
 Maximum memory depth: Standard 2 Mpts, optional 4 Mpts and optional segment memory.
 Waveform update rate: > 1 million waveforms per second.
 Time base range: 2 ns/div to 50 s/div.
 Channel-to-channel deskew range: ± 100 ns.
 Time base accuracy: 25 ppm ± 5 ppm per year (aging).
 Delta Time accuracy (using cursors): ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps.
 
 Horizontal system digital channels.
 Maximum sample rate: 1 GSa/s.
 Maximum record length: 2 Mpts (digital only), 500 kpts (analog and digital channels).
 Minimum detectable pulse width: 5 ns.
 Channel-to-channel skew: 2 ns (typical); 3 ns (maximum).
 
 
 
 |