Keysight (Agilent) N9916A CALIBRATION and Keysight (Agilent) N9916A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N9916A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) N9916A   Description / Specification:    
Keysight (Agilent) N9916A 14 GHz FieldFox Handheld RF Combination Analyzer

The Agilent N9916A 14 GHz FieldFox Handheld RF Combination Analyzer is designed to withstand your toughest working conditions. To accelerate your work, each operating mode has a task-driven user interface that saves time in the field. Step up to FieldFox – and boost your readiness. The combination analyzer's base function is a cable and antenna analyzer and it can be configured to include a spectrum and network analyzer. FieldFox can be ordered with additional capabilities: power meter, independent signal generator, vector voltmeter, interference analyzer, variable DC source, and built-in GPS receiver. Specifications. Frequency range: 30 kHz to 14 GHz. Frequency reference Accuracy: ± 0.7 ppm (spec) + aging. Frequency Resolution: 1 Hz (Frequency <= 5 GHz), 1.34 Hz (Frequency <=10 GHz), 2.68 Hz (Frequency >10 GHz). Resolution (Number of data points): 101, 201, 401, 601, 801, 1001, 1601, 4001, 10,001, Arbitrary number of points settable through SCPI. Test port output power Port 1 or port 2, high power, 23 ± 5 °C: -3 dBm (> 300 kHz to 2 MHz), -2 dBm (> 2 MHz to 625 MHz), +1 dBm (> 625 MHz to 3 GHz), -1 dBm (>= 3 to 6.5 GHz), -2 dBm (>= 6.5 to 9 GHz), -4 dBm (>= 9 to 14 GHz). Power level accuracy: ± 1.5 dB at -15 dBm, typical. Resolution Bandwidth (RBW) Range (–3 dB bandwidth) Zero Span: 10 Hz to 5 MHz in 1, 3, 10 sequence. Maximum Safe Input Level Average CW Power: +27 dBm (0.5 W). Options. 010, Network analyzer time domain. 030, Remote Control Capability. 112, QuickCal. 210, Vector network analyzer transmission/reflection. 211, Vector network analyzer full 2-port S-parameters. 233, Spectrum analyzer. 235, Preamplifier. 236, Interference analyzer and spectrogram. 238, Spectrum Analyzer Time Gating. 302, USB power sensor support. 307, GPS receiver. 308, Vector voltmeter. 309, DC bias variable-voltage source. 310, Built-in power meter.



 

Standard Calibration $605.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N9916A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) N9916A CALIBRATION and/or Keysight (Agilent) N9916A 14 GHz FieldFox Handheld RF Combination Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: