Keysight (Agilent) 53230A CALIBRATION and Keysight (Agilent) 53230A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53230A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53230A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 53230A 2- Ch 350 MHz Universal Frequency Counter/Timer

The 53220A 350 MHz Universal Frequency Counter/Timer, 12 digits/sec, 20 ps is a two-channel frequency counter with the ability to make all the frequency and time interval measurements you depend on. An optional microwave channel can be added to measure 6 or 15 GHz. Input Channel Characteristics. Channels: Ch 1 & Ch 2 Standard (DC - 350 MHz), Ch 3 Optional (6 or 15 GHz). Frequency range DC coupled: DC (1 mHz) to 350 MHz (2.8 ns to 1000 sec). Frequency range AC coupled: 50 ohm or 1 Mohm 10 Hz - 350 MHz. Input range: ±5 V (±50 V) full scale ranges. Sensitivity (typ): 20 mVpk (DC - 100 MHz), 40 mVpk (> 100 MHz). Noise: 500 µVrms (max), 350 µVrms (typ). Input event Threshold levels: ±5 V (±50 V) in 2.5 mV (25 mV) steps. Maximum input 50 ohm damage level: 1 W. Frequency, period (average) measurements Ch 1, Ch 2 or optional Ch 3: 12 digits/s. Frequency, period Range: DC (1 mHz) to 350 MHz (2.8 ns to 1000 s). Gate Source: Time, external. Gate time (step size): 1 µs - 1000 s (1 µs). Trigger source: Internal, external, bus, manual. Timebase reference: Internal, external, or auto. Display: 4.3" Color TFT WQVGA (480 x 272), LED backlight. Programming interface: 10/ 100/ 1000 LAN (LAN Sockets and VXI-11 protocol), USB 2.0 (USB-TMC488 protocol), GPIB (IEEE-488.1, IEEE-488.2 protocol). Options. Option 010 Ultra-high-stability OCXO timebase. Option 106 6 GHz microwave input. Option 115 15 GHz microwave input. Option 150 Pulse microwave measurements. Option 201 Add rear panel parallel inputs for baseband channels. Option 202 Optional microwave input - front Type N (default if 106 or 115 ordered). Option 203 Optional microwave input - rear panel SMA(f) connector. Option 300 Add internal lithium ion smart battery and charger for unstable AC power or timebase stability.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53230A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 53230A CALIBRATION and/or Keysight (Agilent) 53230A 2- Ch 350 MHz Universal Frequency Counter/Timer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: