Keysight (Agilent) 53230A CALIBRATION and Keysight (Agilent) 53230A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53230A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53230A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 53230A 2- Ch 350 MHz Universal Frequency Counter/Timer

The 53220A 350 MHz Universal Frequency Counter/Timer, 12 digits/sec, 20 ps is a two-channel frequency counter with the ability to make all the frequency and time interval measurements you depend on. An optional microwave channel can be added to measure 6 or 15 GHz. Input Channel Characteristics. Channels: Ch 1 & Ch 2 Standard (DC - 350 MHz), Ch 3 Optional (6 or 15 GHz). Frequency range DC coupled: DC (1 mHz) to 350 MHz (2.8 ns to 1000 sec). Frequency range AC coupled: 50 ohm or 1 Mohm 10 Hz - 350 MHz. Input range: ±5 V (±50 V) full scale ranges. Sensitivity (typ): 20 mVpk (DC - 100 MHz), 40 mVpk (> 100 MHz). Noise: 500 µVrms (max), 350 µVrms (typ). Input event Threshold levels: ±5 V (±50 V) in 2.5 mV (25 mV) steps. Maximum input 50 ohm damage level: 1 W. Frequency, period (average) measurements Ch 1, Ch 2 or optional Ch 3: 12 digits/s. Frequency, period Range: DC (1 mHz) to 350 MHz (2.8 ns to 1000 s). Gate Source: Time, external. Gate time (step size): 1 µs - 1000 s (1 µs). Trigger source: Internal, external, bus, manual. Timebase reference: Internal, external, or auto. Display: 4.3" Color TFT WQVGA (480 x 272), LED backlight. Programming interface: 10/ 100/ 1000 LAN (LAN Sockets and VXI-11 protocol), USB 2.0 (USB-TMC488 protocol), GPIB (IEEE-488.1, IEEE-488.2 protocol). Options. Option 010 Ultra-high-stability OCXO timebase. Option 106 6 GHz microwave input. Option 115 15 GHz microwave input. Option 150 Pulse microwave measurements. Option 201 Add rear panel parallel inputs for baseband channels. Option 202 Optional microwave input - front Type N (default if 106 or 115 ordered). Option 203 Optional microwave input - rear panel SMA(f) connector. Option 300 Add internal lithium ion smart battery and charger for unstable AC power or timebase stability.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53230A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 53230A CALIBRATION and/or Keysight (Agilent) 53230A 2- Ch 350 MHz Universal Frequency Counter/Timer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: