Keysight (Agilent) N9010A CALIBRATION and Keysight (Agilent) N9010A REPAIR

The Keysight (Agilent) N9010A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N9010A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   Keysight (Agilent) N9010A   Description / Specification:   Spec Sheet 
Keysight (Agilent) N9010A EXA X-Series Signal Analyzer

The Agilent N9010A EXA X-Series Signal Analyzer includes a list-sweep mode that lets you quickly perform power measurements at discrete frequency points. The fast sweep capability (1.5 seconds for a 26.5-GHz full-span sweep with 20 kHz RBW), available on the EXA with select option, saves significant amount of test time in your spurious response measurements. For devices that require multiple measurement applications, 30-ms mode switching helps you reduce overall test time. The Agilent N9010A delivers power meter-class level accuracy with ± 0.27 dB absolute amplitude accuracy. The EXA also makes it easy to characterize spurious response with typical displayed average noise level (DANL) of -163 dBm at 2 GHz and -156 dBm at 26.5 GHz. Excellent third-order intercept (TOI) performance (+19 dBm for the millimeter-wave models or +18 dBm for the RF/microwave models) helps to achieve the dynamic range demanded for accurately measuring the smallest signals in presence of the larger signal. To ensure accurate verification of, for example, oscillator performance, get typical phase noise specifications of -106 dBc/Hz with the millimeter-wave models or -105 dBc/Hz with the RF/microwave models (10-kHz offset from a 1-GHz carrier).
Specifications.

Frequency ranges: 10 Hz to 3.6, 7.0, 13.6, or 26.5 GHz (option specific).
Analysis bandwidth: 25 MHz (standard), 40 MHz (optional).
Displayed average noise level (DANL): -163 dBm at 1 GHz, -156 dBm at 26.5 GHz preamplifier on.
Third-order intermodulation (TOI) distortion: +18 dBm at 1 GHz.
W-CDMA ACLR dynamic range: 68 dBc (73 dBc with noise correction on).
Phase noise: -105 dBc/Hz (10 kHz offset, 1 GHz carrier).
Amplitude accuracy: ± 0.27 dB (95th percentile to 3.6 GHz).

Options.
N9010A-503 Frequency range, 10 Hz to 3.6 GHz.
N9010A-507 Frequency range, 10 Hz to 7 GHz.
N9010A-513 Frequency range, 10 Hz to 13.6 GHz.
N9010A-526 Frequency range, 10 Hz to 26.5 GHz.
N9010A-532 Frequency range, 10 Hz to 32 GHz.
N9010A-544 Frequency range, 10 Hz to 44 GHz.
N9010A-B25 Analysis bandwidth, 25 MHz.
N9010A-B40 Analysis bandwidth, 40 MHz.
N9010A-CR3 Connector, Wideband IF output.
N9010A-CRP Connector, programmable rear IF output.
N9010A-DP2 Digital Processor, 2 GB Capture Memory.
N9010A-DVR DVD-ROM/CD-R/RW Drive.
N9010A-EA3 Electronic attenuator, 3.6GHz.
N9010A-EDP Enhanced display package.
N9010A-EMC Basic EMC Functionality.
N9010A-ESC External source control.
N9010A-EXM External Mixing.
N9010A-FSA Fine resolution step attenuator.
N9010A-MLP Minimum loss pad, 50 to 75 ohm.
N9010A-MPB Microwave preselector bypass.
N9010A-P03 Preamplifier, 3.6 GHz.
N9010A-P07 Preamplifier, 7 GHz.
N9010A-P13 Preamplifier, 13.6 GHz.
N9010A-P26 Preamplifier, 26.5 GHz.
N9010A-PC4 Dual core high performance processor, 8GB RAM, removable SSD.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N9010A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your Keysight (Agilent) N9010A CALIBRATION and/or Keysight (Agilent) N9010A EXA X-Series Signal Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: