Keysight (Agilent) DSA90404A CALIBRATION and Keysight (Agilent) DSA90404A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSA90404A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSA90404A   Description / Specification:   Spec Sheet 
Keysight (Agilent) DSA90404A 4 Ch 4 GHz Infiniium Oscilloscope

The Agilent DSA90404A 4 Ch 4 GHz Infiniium Oscilloscope boasts an ever-expanding set of measurement applications for serial debugging and protocol viewing, jitter testing, advanced triggering, measurement customization, and rapid automation. With 1 Gbyte of memory, low-frequency jitter components can be more quickly resolved in a single measurement. Statistical accuracy is improved with more data collection. Agilent's integrated deep memory remains responsive and allows more comprehensive testing, supporting pattern lengths up to PRBS23 for accurate transmitter and receiver results. Infiniium's built-in FFT allows users to quickly and easily analyze the frequency components of their signals. A resolution bandwidth of 6 kHz is supported with the standard 10 Megabytes of acquisition memory at the maximum sample rate of 20 GSa/s. Performance characteristics. Analog bandwidth (-3 dB): 4 Ghz. Rise time/fall time: 105 ps (10 - 90%), 79 ps (20 - 80%). Input impedance: 50 ohm, ± 3%. Sensitivity: 1 mV/div to 1 V/div. Input coupling: DC. Vertical resolution: 8 bits, >= 12 bits with averaging. DC gain accuracy: ± 2% of full scale at full resolution channel scale (± 2.5% for 5mV/div). Maximum input voltage: ± 5 V. Dynamic range: ± 4 div from center screen. RMS noise floor (scope only): 199 µV (Volts/div, 5 mV), 15.6 µV (Volts/div, 1 V). Main timebase range: 5 ps/div to 20 s/div real-time, 5 ps/div to 500 ns/div equivalent-time. Main timebase delay range: -200 s to 200 s real-time, -25 µs to 200 s equivalent-time. Zoom timebase range: 1 ps/div to current main time scale setting. Channel deskew: ± 25 µs range, 100 fs resolution. Time scale accuracy: ± (0.4 + 0.5 * YrsSinceCal) ppm pk. Maximum real-time sample rate: 20 GSa/s (4 channels simultaneously). Memory depth per channel Standard: 50 Mpts on 4 channels. Display: 12.1-inch color XGA TFT-LCD with touch screen. The DSA90404A comes with standard 50 Mpts memory, high speed serial data analysis (Option 003/E2688A), EZJIT Complete jitter analysis software (Option 070/N8823A), EZJIT Plus jitter analysis software (Option 004/N5400A), and EZJIT jitter analysis software (Option 002/E2681A).



 

Standard Calibration $565.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSA90404A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) DSA90404A CALIBRATION and/or Keysight (Agilent) DSA90404A 4 Ch 4 GHz Infiniium Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: