Keysight (Agilent) N2781B CALIBRATION and Keysight (Agilent) N2781B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N2781B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Accessory?
Shop for Comparable Products on our
 used Oscilloscope Accessory page

 
   Keysight (Agilent) N2781B   Description / Specification:    
Keysight (Agilent) N2781B 10 MHz/150A AC/DC Current Probe

The Agilent N2781B AC/DC Current Probe is compatible with any oscilloscope with high impedance BNC input, the new N2781B current probe offers accurate and reliable solution for measuring ac and dc currents. It features broad measurement ranges (up to 150 A), flat frequency response, low noise and low insertion loss that make the probes ideal for current measurements in areas such as measuring steady state or transient current of motor drives, switching power supplies, inverters, controllers, sensors, disk drives, LCD displays, electronic ballasts and amplifiers. Specifications. Bandwidth (-3dB): DC to 10 MHz. Risetime: 35 ns or less. Maximum current (continuous) RMS: 150A. Maximum peak current (non-continuous): 300 A peak. Lowest measurable current (at ±3% accuracy at DC, scope set to 1 mV/div and high-resolutionmode on): 20 mA. Output voltage rate: 0.01 V/A (100:1). Max input voltage (Insulated conductor should be used): 600 V CAT II, 300 V CAT III. Amplitude accuracy (DC and 45 to 66 Hz, rated current): ±1.0% rdg. ± 100 mA. Noise (measured with 20 MHz bandwidth limit filter on the scope): Equivalent to 25 mArms or less. Maximum rated power: 5.5 VA (with rated current).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N2781B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) N2781B CALIBRATION and/or Keysight (Agilent) N2781B 10 MHz/150A AC/DC Current Probe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: