Keysight (Agilent) N2780B CALIBRATION and Keysight (Agilent) N2780B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N2780B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Accessory?
Shop for Comparable Products on our
 used Oscilloscope Accessory page

 
   Keysight (Agilent) N2780B   Description / Specification:    
Keysight (Agilent) N2780B 2 MHz/500A AC/DC Current Probe

The Agilent N2780B AC/DC Current Probe is compatible with any oscilloscope with high impedance BNC input, the new N2780B current probe offers accurate and reliable solution for measuring ac and dc currents. It features broad measurement ranges (up to 500 A), flat frequency response, low noise and low insertion loss that make the probes ideal for current measurements in areas such as measuring steady state or transient current of motor drives, switching power supplies, inverters, controllers, sensors, disk drives, LCD displays, electronic ballasts and amplifiers. Specifications. Bandwidth (-3dB): DC to 2 MHz. Risetime: 175 ns or less. Maximum current (continuous) RMS: 500A. Maximum peak current (non-continuous): 700 A peak. Lowest measurable current (at ±3% accuracy at DC, scope set to 1 mV/div and high-resolutionmode on): 20 mA. Output voltage rate: 0.01 V/A (100:1). Max input voltage (Insulated conductor should be used): 600 V CAT II, 300 V CAT III. Amplitude accuracy (DC and 45 to 66 Hz, rated current): ±1.0% rdg. ± 500 mA. Noise (measured with 20 MHz bandwidth limit filter on the scope): Equivalent to 25 mArms or less. Maximum rated power: 7.2 VA (with rated current).



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N2780B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) N2780B CALIBRATION and/or Keysight (Agilent) N2780B 2 MHz/500A AC/DC Current Probe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: