Keysight (Agilent) N5222A CALIBRATION and Keysight (Agilent) N5222A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N5222A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) N5222A   Description / Specification:    
Keysight (Agilent) N5222A 26.5 GHz PNA Microwave Network Analyzer

The Agilent N5222A 26.5 GHz PNA Microwave Network Analyzer features a built-in S-parameter test set, one or two synthesized sources used for device stimulus, a solid-state drive, USB interfaces, and a 10.4” LCD touch screen display. It has 50 ohm, ruggedized 3.5 mm (m) test ports. The Agilent N5222A is used to test a wide variety of passive and active devices such as filters, duplexers, amplifiers and frequency converters. The high-performance characteristics of the PNA make it an ideal solution for these types of component characterizations as well as millimeter-wave, signal integrity and materials measurements. Specifications. Frequency Range: 10 MHz to 26.5 GHz. Frequency Resolution: 1 Hz. Frequency Accuracy: +/- 1 ppm. Maximum Leveled Power 50 MHz to 16 GHz: 13 dBm (Port 1, Port 3, Port 2, Port 4). Power Level Accuracy: +/- 1.0 (10 MHz to 10 GHz), +/- 1.2 (10 GHz to 13.5 GHz), +/- 2.0 (13.5 GHz to 18 GHz), +/- 2.5 (18 GHz to 26.5 GHz). Power Sweep Range 50 MHz to 16 GHz: 38 dB (Port 1, Port 3, Port 2, Port 4). Power Resolution: 0.01 dB. Maximum Settable Power: 30 dBm. 2nd and 3rd Harmonics at Max Specified Power 4 GHz to 24 GHz: -19 dBc. Test Port Noise Floor @ 10 Hz IFBW, 500 MHz to 20 GHz: -114 dBm. Damage Input Level: 30 dBm. System IF Bandwidth Range: 1 Hz to 15 MHz, nominal. RF Connector Type: 3.5 mm (male), 50 ohm, (nominal). Options. 008 - Pulsed RF Measurements. 010 - Time Domain. 021 - Add pulse modulator to internal first source. 022 - Add pulse modulator to internal second source. 025 - Add four internal pulse generators. 028 - Noise figure measurements using standard receivers. 080 - Frequency offset measurements. 082 - Scalar calibrated converter measurements. 083 - Vector and scalar calibrated converter measurements. 084 - Embedded LO measurements. 086 - Gain compression application. 087 - Intermodulation distortion measurements. 088 - Source phase control. 118 - Fast CW Mode. 200 - 2 ports, single source, base hardware configuration. 201 - 2 ports, single source, with configurable test set. 210 - 2 ports, single source, with metrology configuration. 217 - 2 ports, single source, configurable test set, extended power range. 400 - 4 ports, dual source, base hardware configuration. 401 - 4 ports, dual source, with configurable test set. 410 - 4 ports, dual source, with metrology configuration. 460 - Integrated true-mode stimulus application. 551 - N-port calibrated measurements.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N5222A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your Keysight (Agilent) N5222A CALIBRATION and/or Keysight (Agilent) N5222A 26.5 GHz PNA Microwave Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: