A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N9310A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) N9310A   Description / Specification:   Spec Sheet 
Keysight (Agilent) N9310A 3  GHz RF Signal Generator

The Agilent N9310A is a general purpose RF signal generator covering a frequency range from 9 kHz to 3 GHz. It's suited for R&D, manufacturing, education, and service maintenance. Specifications. Frequency Range: 9 kHz to 3.0 GHz. Frequency Resolution: 0.1 Hz. Frequency Switching speed: < 10 ms, Within 0.1 ppm of final frequency. Frequency reference Aging rate: ±1 ×10^-6 / year. Timebase reference output Frequency: 10 MHz. Timebase reference Amplitude: > 0.35 Vrms level into 50 ohm. External reference input Range: 2 MHz, 5 MHz, 10 MHz. External reference input Amplitude: 0.5 to 2 Vrms. Output Power: –127 to +13 dBm, +20 dBm settable. Output Resolution: 0.1 dB. Output Accuracy: < ±1dB Fc >= 100 kHz, –120 <= Level <= +13 dBm, 20 to 30 °C. Reversal power protection DC voltage: 30 V. Reversal power protection RF power: +36 dBm, 1 minute; the warning for reversed power protection is nominally at +25 dBm. SSB phase noise: < –95 dBc/Hz, Typical, Fc = 1 GHz at 20 kHz offset. Harmonics: < –30 dBc, Level <= 0 dBm, Fc >= 1 MHz. Amplitude modulation (Fc >= 100 kHz) Range: 0 to 100%, Envelope peak < maximum specified power. Frequency modulation (Fc >=100 kHz) Frequency deviation: 20 Hz to 100 kHz. Phase modulation (Fc >=100 kHz) Phase deviation: 0 to 10 rad (Rate <= 10 kHz), 0 to 5 rad (10 kHz < rate <= 20 kHz). Pulse modulation On/Off ratio: >= 40 dB. Standard USB connectivity for test automation and flash memory support. Options. 001, Add Analog IQ Input Capability. PFR, Precision frequency reference.



 

Standard Calibration $825.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N9310A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) N9310A CALIBRATION and/or Keysight (Agilent) N9310A 3 GHz RF Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: