Keysight (Agilent) MSOX92004A CALIBRATION and Keysight (Agilent) MSOX92004A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) MSOX92004A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) MSOX92004A   Description / Specification:   Spec Sheet 
Keysight (Agilent) MSOX92004A 4+16 Ch 20 GHz Infiniium Mixed Signal Oscilloscope

The Agilent MSOX92004A 4+16 Ch 20 GHz Infiniium Mixed Signal Oscilloscope is engineered for 33 GHz true analog bandwidth that delivers. It comes with more than 15 protocol decoders, including the industry’s only 64/66b decoder. The 90000 X-Series protocol tools feature time-correlated markers that let you easily move between the listing window and the waveform. Protocol tools can be used on up to four lanes simultaneously. A 10 MHz reference clock can be input to or output from the scope to allow precise timebase synchronization with more than one oscilloscope, RF instruments or logic analyzers. Serial data equalization for the 90000 X-Series provides fast and accurate equalization using decision feedback equalization (DFE), feed-forward equalization (FFE), and continuous time linear equalization (CTLE) modeling in real time. Serial data equalization software allows you to input your own self-designated tap values to verify your design. Performance characteristics. Analog bandwidth (-3 dB): 20 GHz (2 channel), 16 GHz (4 channel). Rise time/fall time: 20 ps (10 - 90%), 15 ps (20 - 80%). Input impedance: 50 ohm, ± 3%. Sensitivity: 1 mV/div to 1 V/div. Input coupling: DC. Vertical resolution: 8 bits, >= 12 bits with averaging. DC gain accuracy: ± 2% of full scale at full resolution channel scale (± 2.5% for 5mV/div). Maximum input voltage: ± 5 V. Dynamic range: ± 4 div from center screen. RMS noise floor (scope only): 0.43 V (Volts/div, 10 mV), 30.05 V (Volts/div, 1 V). Main timebase range: 2 ps/div to 20 s/div real-time. Main timebase delay range: -200 s to 200 s real-time. Zoom timebase range: 1 ps/div to current main time scale setting. Channel deskew: ±1 ms range, 10 fs resolution. Time scale accuracy: ± [0.1 ppm (immediately after calibration) ±0.1 ppm/year (aging)]. Maximum real-time sample rate: 40 GSa/s (4 channels simultaneously), 80 GSa/s (2 channels simultaneously). Memory depth per channel Standard: 50 Mpts on 4 channels, 100 Mpts on 2 channels. Digital Input Channels: 16. Threshold groupings: 2 individual threshold settings (1 for channels 0-7 and 1 for channels 8-15). Threshold selections TTL (1.4V), CMOS, (2.5V), ECL (-1.3V), PECL (3.7V), user defined (±3.00 V in 100 mV increments). Analog bandwidth: 3 GHz (depends on probing). Digital Channels Maximum real time sample rate: 10 GSa/s at 16 channels, 20 GSa/s at 8 channels. Digital Channels Maximum memory depth per channel: Up to 1 Gpt. Digital Channels Minimum width glitch detection: 50 pS. Display: 12.1-inch color XGA TFT-LCD with touch screen.



 

Standard Calibration $1,000.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) MSOX92004A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) MSOX92004A CALIBRATION and/or Keysight (Agilent) MSOX92004A 4+16 Ch 20 GHz Infiniium Mixed Signal Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: