Keysight (Agilent) 3325B REPAIR and Keysight (Agilent) 3325B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3325B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3325B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 3325B   Description / Specification:    
Keysight (Agilent) 3325B Synthesizer/Function Generator

HP 3325B Synthesizer/Function Generator, frequency accuracy is determined by a precision frequency reference and output can be set with a resolution of 1?Hz. The phase of the output signal can be precisely controlled ±719.9° with 0.1° resolution, and multiple HP 3325Bs can be locked together for multi-phase applications. Option 001 High Stability Frequency Reference. Option 002 High Voltage Output. Waveforms: Sine, square, triangle, negative and positive ramps. Frequency Range; Sine: 1?Hz to 20.999 999 999 MHz, Square: 1?Hz to 10.999 999 999 MHz, Triangle/Ramps: 1?Hz to 10.999 999 999 kHz. Frequency Resolution: 1?Hz < 100kHz ; 1 mHz >= 100 kHz. Frequency Accuracy: ±5 x 10 -6, 20° to 30°C at time of calibration. Main Signal Output (all waveforms): Impedance: ohm. Amplitude Range: 1 mV to 10 V p-p in 8 amplitude ranges, 1-3-10 sequences (10 dB steps), into 50 ohm load. Amplitude Resolution: 0.03% of full range or 0.01 dB (4 digits). Amplitude Accuracy (without dc offset, relative to programmed amplitude and accuracy). Sine-wave Amplitude Accuracy: 1 MHz to 100 kHz: ±0.1 dB, >= 3V p-p; ±0.2 dB, < 3 V p-p (100 kHz to 20 MHz: ±0.4 dB, >= 3 V p-p; ±0.6 dB, 0.1 to 3 V p-p). Sine-wave Spectral Purity Phase Noise: -60 dB for a 30 kHz band centered on a 20 MHz carrier (excluding ±1 Hz about the carrier) with high-stability Option 001 installed. Sweep Time Linear: 0.01 s to 1000s. Modulation Source; Frequency Range: Sine 0.1 Hz to 10 kHz, square 0.1 Hz to 2 kHz. Frequency Accuracy: 0.1%, typical. Impedance: Drives 10 k ohm or greater load. Sine-wave Purity: -34 dBc or better, typical. Waveforms: Sine, square, arbitrary



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3325B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 3325B REPAIR and/or Keysight (Agilent) 3325B Synthesizer/Function Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: