Keysight (Agilent) N4421B CALIBRATION and Keysight (Agilent) N4421B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N4421B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another S-Parameter Test Set?
Shop for Comparable Products on our
 used S-Parameter Test Set page

 
   Keysight (Agilent) N4421B   Description / Specification:   Spec Sheet 
Keysight (Agilent) N4421B 50 ohm 50 GHz S-Parameter Test Set

The Agilent N4421B S-parameter test set, combined with a 2-port PNA or PNA-L network analyzer and Option 550, offers a complete solution for 4-port measurements. Solid-state switches for fast and reliable measurement. Balanced measurement capability. Test set typical performance. Frequency range: 10 MHz to 50 GHz. Transition time: (10 to 90%) 14 ps. Impedance: 50 Ohms (nom). Maximum operating level: +20 dBm. Damage level: +30 dBm. Test port connectors: 2.4 mm (m). RF connectors: 2.4 mm (f). Dynamic range: Transmission measurements at 10 Hz IF bandwidth, with four-port error correction. Option 525: Front panel access to source output, receiver inputs and couplers for a custom test set. Adds source attenuators for wider source power output. Compatible network analyzers, N5230A. Option 550: Enables full, 4-port error correction and differential measurements on a 2-port network analyzer. External test set required. Compatible network analyzers, E8362/3/4B, E8361A, N5230A. Option 014: Provides front panel access to source output, receiver inputs and couplers to configure a custom test set. Compatible network analyzers, E8362/3/4B, E8361A, N5250A.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N4421B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your Keysight (Agilent) N4421B CALIBRATION and/or Keysight (Agilent) N4421B 50 ohm 50 GHz S-Parameter Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: