Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3458A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3458A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) 3458A   Description / Specification:    
Keysight (Agilent) 3458A 8 1/2 Digit Digital Multimeter

The HP 3458A 8 1/2 Digit Multimeter has high-test system throughput with up to 100,000 reading/s, Internal test setups > 340/s and Programmable integration times from 500 ns to 1 s.

Performance Features.

DC Volts.
5 Reading Ranges, from 0.1 V to 1000 V
8 1/2 to 4 1/2 digits resolution
Up to 100,000 readings/s (4 1/2 digits)
Maximum sensitivity: 10 nV.
0.6 ppm best 24-hr accuracy.
8 ppm (4 ppm opt)/yr voltage reference stability.

Resistance.
9 Reading Ranges, from 10 ohm to 1 Gohm.
2-wire and 4-wire ohm with offset compensation
Up to 50,000 readings/s (5 1/2 digits)
Maximum Sensitivity: 10 µ ohm
2.2 ppm best 24-hour accuracy

AC Voltage.
6 Reading Ranges, from 10 mV to 1000 V.
Bandwidth Range: 1 Hz to 10 MHz
Up to 50 readings/second
Choice of sampling or analog true rms techniques
100 ppm best 24-hr accuracy

DC Current.
8 Reading Ranges, from 100 nA to 1 A
Up to 1,350 readings/second (5 1/2 digits)
Maximum Sensitivity: 1 pA
14 ppm best 24-hr accuracy

AC Current.
5 Reading Ranges, from 100 µA to 1 A
Bandwidth Range: 10 Hz to 100 kHz
Up to 50 readings/second
500 ppm best 24-hr accuracy

Frequency / Period.
AC or DC coupled
Voltage Frequency Range: 1 Hz to 10 MHz
Voltage Period Range: 100 ns to 1 s
Current Frequency Range: 1 Hz to 100 kHz
Current Period Range: 10 µs to 1 s
0.01% best 24-hr accuracy

Some Common Errors.
200 Isolator Does Not Respond
201 Nonvolatile RAM DTACK
202 Slave Self Test
204 DC VOS DAC Convergence
205 Test Value Out of Range
206 HPIB ASM
207 UART INTR
208 Timer INTR
210 ROM 0 LOW CHECKSUM
211 ROM 0 HIGH CHECKSUM
212 NONVOLATILE RAM LOW
213 Optional RAM 0 High
214 Optional RAM 0 Low



 

Standard Calibration $780.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3458A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 3458A REPAIR and/or Keysight (Agilent) 3458A 8 1/2 Digit Digital Multimeter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: