LECROY WAVEPRO 940 CALIBRATION and LECROY WAVEPRO 940 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the LECROY WAVEPRO 940 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   LECROY WAVEPRO 940   Description / Specification:    
LECROY WAVEPRO 940 4 Ch 500 MHz WavePro Digital Oscilloscope

The Lecroy WavePro 940 4 channel 500 MHz oscilloscope uses high-speed 16 GS/s A-to-D converters and 64 Mpts deep memory. Specifications. Channels: 4. Bandwidth (-3dB): 500 MHz @ 50 ohms and at probe tip with PP005. Bandwidth Limiter: 20 MHz or 200 MHz. Input Impedance: 50 ohms ±1.5%; 10 M-ohm, 11 pF typical (using PP005 probe). Input Coupling: AC, DC, GND (1 M-ohm), DC, GND (50 ohms). Max Input: 5 V rms (50 ohms), 100 V max (peak AC <= 5 kHz + DC)(1 M-ohm). Vertical Resolution: 8 bits; up to 11 bits with enhanced resolution (ERES). Sensitivity: 1 mV to 1 V/div fully variable (50 ohms), 1 mV to 2 V/div fully variable (1 M-ohm). DC Accuracy: ±2.0% of full scale +1.5% offset value @ gain > 10 mV. Offset Accuracy: ±(1.5% + 0.5% of full scale + 1 mV). Isolation – channel to channel: > 250:1 at same V/div settings. Timebases: Main and up to four zoom traces simultaneously. Time/Div Range: 200 ps/div to 1000 s/div. Clock Accuracy: <= 10 ppm. Interpolator Resolution: 5 ps. Max Sample Rate: 8 GS/s (2 Ch). Trigger Modes: NORMAL, AUTO, SINGLE and STOP. Maximum Trigger Frequency: Triggers up to maximum bandwidth (HF), or 1 GHz (AC, DC).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the LECROY WAVEPRO 940. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your LECROY WAVEPRO 940 CALIBRATION and/or LECROY WAVEPRO 940 4 Ch 500 MHz WavePro Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: