|
|
The Agilent MSOX3052A X-Series’s Oscilloscope innovation starts with 5-instruments-in-1 integration. The one million waveforms per second update rate is 20 times faster than the competition to display the most signal detail. The 3000 X-Series provides maximum investment protection with fully-upgradable 5-instruments-in-1; even bandwidth is upgradable. The InfiniiVision MSOX3052A X-Series comes with a large 8.5-inch WVGA display so you can view analog, digital and serial signals easily on the screen. With up to 4 Mpts of MegaZoom IV deep memory, you can capture long, non-repeating signals while maintaining a high sample rate, then quickly zoom in on areas of interest. Specifications. Analog Bandwidth (– 3 dB): 500 MHz. Analog Input channels: 2. Calculated rise time (10-90%): <= 800 ps. Hardware bandwidth limits: Approximately 20 MHz (selectable). Input coupling: AC, DC. Input impedance Selectable: Selectable: 1 Mohm ± 1%; 50 ohm ± 1.5% Sample rate on each channel: 2 GSa/s per channel, 4 GSa/s interleaved. Memory depth (record length): Up to 4 Mpts. Display: 8.5-inch WVGA with 64 levels of intensity grading. Waveform update rate (max): 1,000,000 waveforms/s. Vertical resolution: 8 bits. Horizontal resolution: 2.5 ps. Maximum input voltage: 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk, With N2862A, N2863A or N2890A 10:1 probe: 300 Vrms. DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]. DC vertical gain accuracy: ± 2.0% full scale. Offset range: ±2 V (2 mV/div to 200 mV/div), ±50 V (> 200 mV/div to 5 V/div). DC vertical offset accuracy: ±0.1div ± 2mV ± 1% of offset setting. Vertical system digital channels. Digital input channels: 16 digital (D0 to D15). Thresholds: Threshold per set of 8 channels. Threshold selections: TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (–1.3 V), User-definable (selectable by pod). User-defined threshold range: ±8.0 V in 10 mV steps. Maximum input voltage: ±40 V peak CAT I; transient overvoltage 800 Vpk. Threshold accuracy: ±(100 mV + 3% of threshold setting). Maximum input dynamic range: ±10 V about threshold. Minimum voltage swing: 500 mVpp. Horizontal system analog channels. Maximum sample rate: 4 GSa/s half channel, 2 GSa/s all channel. Maximum memory depth: Standard 2 Mpts, optional 4 Mpts and optional segment memory. Waveform update rate: > 1 million waveforms per second. Time base range: 1 ns/div to 50 s/div. Channel-to-channel deskew range: ± 100 ns. Time base accuracy: 25 ppm ± 5 ppm per year (aging). Delta Time accuracy (using cursors): ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps. Horizontal system digital channels. Maximum sample rate: 1 GSa/s. Maximum record length: 2 Mpts (digital only), 500 kpts (analog and digital channels). Minimum detectable pulse width: 5 ns. Channel-to-channel skew: 2 ns (typical); 3 ns (maximum).
|