Keysight (Agilent) 3561A REPAIR and Keysight (Agilent) 3561A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3561A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3561A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   Keysight (Agilent) 3561A   Description / Specification:    
Keysight (Agilent) 3561A Dynamic Signal Analyzer

The HP 3561A Dynamic Signal Analyzer provides 80 dB dynamic range with ± 0.15 dB amplitude accuracy. It's set of measurement functions lets you approach problems from several different angles. Spectra can be displayed in a variety of formats and units, including a three·dimensional spectral map. This map displays up to 60 successive spectra and is extremely useful for analyzing transients and monitoring dynamic signals in both electronic and mechanical systems. The HP 3561A also displays time waveforms, and you can observe a signal in both the time and frequency domains simultaneously. Specifications. Frequency Range: 0.000125 Hz to 100 kHz. Frequency Accuracy: ± 0.003% of display center frequency. Frequency Resolution: 0.25% of frequency span. Window: flat top, Hann, uniform, and exponential. Real-time bandwidth: (typical) single display, 3 kHz. Fast average display, 7.5 kHz. Amplitude Measurement range: +27 to -120 dBV noise floor (22.4 Vrms to 1 uV noise floor). Amplitude Dynamic range: 80 dB. Accuracy at the passband center: ±0.15 dB ± .015% of input range +27 to -40 dBV input ranges, ±0.25 dB ±.025% of input range -41 to -51 dBV input ranges. Input. Impedance: 1 x 10^6 ± 5% shunted by 95 pF maximum. Isolation: input low may be connected to chassis ground or floated up to 30 volts rms (42 volts peak) above ground. Coupling: signal may be ac or dc coupled. Low frequency 3-dB point < 1 Hz in ac mode. ICP current: nominal 4 rnA current source provided. Output Source: pseudo· random, random, or impulse. Opt 001 Extended Non·volatile Memory.



 

Standard Calibration $595.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3561A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 3561A REPAIR and/or Keysight (Agilent) 3561A Dynamic Signal Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: