Keysight (Agilent) 3562A REPAIR and Keysight (Agilent) 3562A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 3562A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 3562A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   Keysight (Agilent) 3562A   Description / Specification:    
Keysight (Agilent) 3562A Two-Channel 100 kHz Dynamic Signal Analyzer

The HP 3562A Dynamic Signal Analyzer is a dual-channel fast-Fourier transform-based network, spectrum and waveform analyzer which provides analysis capabilities in both the time and frequency domains. The dc-to-100 kHz frequency range, 150 dB measurement range and 80 dB dynamic range of the analyzer makes it a powerful solution for testing and analysis in electronics, mechanics and electromechanical control systems. Two high performance input channels and a built-in signal source (noise and sine signals) address network analysis on the bench or in a test system. Zoom analysis with frequency resolution to 25.6 µHz plus a powerful AM, FM and PM demodulation function. Specifications. Frequency Measurement Range: 64 µlHz to 100 kHz, both channels, single- or dual-channel operation. Frequency Accuracy: ± 0.004% of frequency reading. Frequency Resolution: Span/800, both channels, single- or dual-channel operation. Typical Real Time Bandwidth: 10kHz single-channel, 5 kHz dual-channel , with fast averaging on. Amplitude Absolute Accuracy: Single Channel (Channel 1 or Channel 2) ± 0.15 dB ± 0.015% of input range (+ 27 dBV to -40 dBV), ± 0.25 dB ± 0.025% of input range (-41 dBV to -51 dBV). Input Impedance: 1 M-ohm ± 5% shunted by 100 pF maximum. Source Types: Band limited, band translated random noise, burst random, sine chirp, burst chirp, fixed sine and swept sine signals are available from the front panel Source output. DC Offset is also userselectable. Output Impedance: 50 ohm ± 5 ohm. Output Level: <= ± 10 V peak (ac + dc) into a >= 10 kohm, <1000 pF load. Maximum current = 50 mA.



 

Standard Calibration $750.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 3562A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 3562A REPAIR and/or Keysight (Agilent) 3562A Two-Channel 100 kHz Dynamic Signal Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: