Keysight (Agilent) E8267D CALIBRATION and Keysight (Agilent) E8267D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E8267D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) E8267D   Description / Specification:    
Keysight (Agilent) E8267D 250 kHz to 13/20/31.8/44 GHz PSG Vector CW Signal Generator

The Agilent E8267D PSG Vector Signal Generator delivers industry-leading output power, superior level accuracy, low phase noise, and precision modulation for accurate characterization of RF and microwave components and devices. It features: CW output from 250 kHz to the highest operating frequency, depending on the option. Frequency resolution to 0.001 Hz. List and step sweep of frequency and amplitude, with multiple trigger sources. User flatness correction. External diode detector leveling. Automatic leveling control (ALC) on and off modes; power calibration in ALC- off mode is available, even without power search. 10 MHz reference oscillator with external output. RS- 232, GPIB, and 10Base-T LAN I/O interfaces.
Specifications.

Frequency range: 250 kHz to 13/20/31.8/44 GHz (option dependent).
Frequency resolution, CW: 0.001 Hz.
High output power: +20 dBm (option dependent).
Spectral purity: -55 dBc (max).

Options.
513, Frequency range from 250 kHz to 13 GHz.
520, Frequency range from 250 kHz to 20 GHz.
532, Frequency range from 250 kHz to 31.8 GHz.
544, Frequency range from 250 kHz to 44 GHz.
602, Internal baseband generator, 64 MSa memory.
003, Digital output connectivity with N5102A.
004, Digital input connectivity with N5102A.
007, Analog ramp sweep.
009, 8 GB removable flash memory.
016, Wideband external I/Q inputs.
403, Calibrated AWGN.
409, Global positioning system (GPS) personality.
423, Scenario generator for GPS personality.
UNX, Ultra low phase noise.
UNY, Enhanced ultra low phase noise.
UNT, AM, FM, phase modulation, and LF output.
UNU, Pulse modulation.
UNW, Narrow pulse modulation.
1ED, Type-N (f) RF output connector.
1EH, Improved harmonics below 2 GHz.
1EM, Moves all front panel connectors to the rear panel.



 

Standard Calibration $1,025.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E8267D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) E8267D CALIBRATION and/or Keysight (Agilent) E8267D 250 kHz to 13/20/31.8/44 GHz PSG Vector CW Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: