Keysight (Agilent) 41421B REPAIR and Keysight (Agilent) 41421B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 41421B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 41421B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   Keysight (Agilent) 41421B   Description / Specification:    
Keysight (Agilent) 41421B Medium Power Source/Monitor Unit

The Agilent / HP 41421B Medium Power Source/Monitor Unit is designed for use with the Agilent / HP 4142B Modular DC Source / Monitor Mainframe. It sources voltage and monitors current, or sources current and monitors voltage. Separate FORCE and SENSE terminals enable Kelvin connections (remote sensing).
Specifications.

Voltage Output/Measurement Range, Resolution and Accuracy.
Range, Set resolution, Measure resolution, Accuracy, Maximum Current.
 ±2 V, 100 μV, 40 μV, ±(0.05% + 1 mV), ±100mA.
 ±20 V, 1 mV, 400 μV, ±(0.05% + 10 mV), ±100mA.
 ±40 V, 2 mV, 800 μV, ±(0.05% + 20 mV), ±50 mA.
 ±100 V, 5 mV, 2 mV, ±(0.05% + 50 mV), ±20 mA.

Current Output/Measurement Range, Resolution and Accuracy.
Range, Set resolution, Measure resolution, Accuracy, Maximum Voltage.
 ±1 nA, 50 fA, 20 fA, ±(1% + 6 pA + 20 fA x Vout), ±100V.
 ±10 nA, 500 fA, 200 fA, ±(1% + 15 pA + 200 fA x Vout), ±100V.
 ±100 nA, 5 pA, 2 pA, ±(0.5% + 100 pA + 2 pA x Vout), ±100V.
 ±1 μA, 50 pA, 20 pA, ±(0.5% + 1 nA + 20 pA x Vout), ±100V.
 ±10 μA, 500 pA, 200 pA, ±(0.2% + 10 nA + 200 pA x Vout), ±100V.
 ±100 μA, 5 nA, 2 nA, ±(0.2% + 100 nA + 2 nA x Vout), ±100V.
 ±1 mA, 50 nA, 20 nA, ±(0.2% + 1 μA + 20 nA x Vout), ±200V.
 ±10 mA, 500 nA, 200 nA, ±(0.2% + 10 μA + 200 nA x Vout), ±100V.
 ±100 mA, 5 μA, 2 μA, ±(0.2% + 100 μA + 2 μA x Vout), ±100V(A =< 20 mA)/ ±40V(50 mA >=A > 20mA)/ ±20V(A > 50 mA).

Current Over-range.
1 nA-100mA range: 15% of range.
100mA range: 0%.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 41421B REPAIR and/or Keysight (Agilent) 41421B Medium Power Source/Monitor Unit CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?