Keysight (Agilent) 33512B CALIBRATION and Keysight (Agilent) 33512B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33512B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33512B   Description / Specification:   Spec Sheet 
Keysight (Agilent) 33512B 20 MHz, 2 Ch Arbitrary Waveform Generator

The Keysight 33512B Waveform Generator with arbitrary capability offers exclusive Trueform Technology that gives it more capability, fidelity and flexibility than traditional DDS waveform generators. It has 17 arbitrary waveforms built-in, including standard waveforms such as sine, square, ramp, PRBS and Gaussian Noise. As well as specialty waveforms: Cardiac, Haversine, and Lorentz. Built-in modulations include AM, FM, PM FSK and PWM.
Specifications.

Maximum frequency: 20 MHz.
Number of channels: two.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, D-Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option MEM) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Counted Burst, Gated Burst.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Frequency range (Vout ≤ 10 Vpp): 1 μHz to 30 MHz, 1-μHz resolution.
Amplitude flatness relative to 1 kHz (Vout ≤ 10 Vpp);
  frequency out < 100 kHz: ± 0.10 dB,
  frequency out 100 kHz to 5 MHz: ± 0.15 dB,
  frequency out 5 MHz to 20 MHz: ± 0.30 dB,
  frequency out 20 MHz to 30 MHz: ± 0.40 dB.
Harmonic distortion typical (Vout ≤ 10 Vpp);
  frequency out < 20 kHz: < -70 dBc,
  frequency out 20 kHz to 100 kHz: < -65 dBc,
  frequency out 100 kHz to 1 MHz: < -50 dBc,
  frequency out 1 MHz to 20 MHz: < -40 dBc,
  frequency out 20 MHz to 30 MHz: < -35 dBc.
THD typical (Vout ≤ 10 Vpp) frequency out = 20 Hz to 20 kHz: <0.04%.
Arbitrary waveform memory (volatile): 1 MSa/channel (16 MSa/channel with Option MEM), 512 sequence steps per channel.
Operating modes: Independent, Coupled parameter(s), Combined (Ch 1 + Ch 2), Equal (Ch 1 = Ch 2), or Differential (Ch 1 = −Ch 2).



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33512B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) 33512B CALIBRATION and/or Keysight (Agilent) 33512B 20 MHz, 2 Ch Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*