Keysight (Agilent) 33611A CALIBRATION and Keysight (Agilent) 33611A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33611A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33611A   Description / Specification:   Spec Sheet 
Keysight (Agilent) 33611A 80 MHz, 1 Ch Arbitrary Waveform Generator

The Keysight 33611A Waveform Generator with arbitrary capability offers exclusive Trueform Technology that gives it more capability, fidelity and flexibility than traditional DDS waveform generators. It has 17 arbitrary waveforms built-in, including standard waveforms such as sine, square, ramp, PRBS and Gaussian Noise. As well as specialty waveforms: Cardiac, Haversine, and Lorentz. Built-in modulations include AM, FM, PM FSK and PWM.
Specifications.

Maximum frequency: 80 MHz.
Number of channels: one.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, D-Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 4 MSa (64 MSa with Option MEM) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Counted Burst, Gated Burst.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Frequency range;
  (Vout ≤ 10 Vpp): 1 μHz to 60 MHz, 1-μHz resolution,
  (Vout ≤ 8 Vpp): 1 μHz to 80 MHz, 1-μHz resolution.
Amplitude flatness relative to 1 kHz (Vout > 1 Vpp);
  frequency out < 10 MHz: ± 0.10 dB,
  frequency out 10 MHz to 60 MHz: ± 0.25 dB,
  frequency out 60 MHz to 80 MHz: ± 0.40 dB.
Harmonic distortion typical (Vout = 10 Vpp);
  frequency out < 1 MHz: -67 dBc,
  frequency out = 1 MHz to 10 MHz: < -51 dBc,
  frequency out > 10 MHz: -39 dBc.
THD typical (Vout > 1 Vpp) frequency out = 20 Hz to 20 kHz: <0.04%.
Arbitrary waveform memory (volatile): 4 MSa/channel (64 MSa/channel with Option MEM), 512 sequence steps per channel.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33611A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 33611A CALIBRATION and/or Keysight (Agilent) 33611A 80 MHz, 1 Ch Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: