Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 4195A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 4195A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 4195A   Description / Specification:    
Keysight (Agilent) 4195A Vector Network / Spectrum Analyzer

Network/Spectrum Analyzer. Source; Frequency: 10Hz to 500MHz, 0.001 Hz resolution. Power: -50 dBm to + 15 dBm, 0.1 dB resolution. Sweep Parameters: Frequency, Power, and DC Bias level. Sweep Types: Linear, Log, cw, program, and partial. 2 outputs. DC Bias level: +/- 40V, 0.01V resolution Receiver; Frequency: 10Hz to 500MHz. Resolution Bandwidth: 3Hz to 300 kHz, 1 or 3 step. Magnitude Ratio Dynamic range >100 dB with 0.001 dB resolution. Phase: +/- 180 degrees with 0.01 degree resolution. Delay : 10 ps to 500 s with 10 ps resolution. Spectrum Measurement; Frequency measurement range 10 Hz to 500 MHz. Resolution: RBW 3 Hz to 300 kHz 1 or 3 step. Amplitude : -135 dBm to +20 dBm. Sweep: Linear, Log, cw, program and partial, Modes: continuous, single, manual



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 4195A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your Keysight (Agilent) 4195A REPAIR and/or Keysight (Agilent) 4195A Vector Network / Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: