Keysight (Agilent) 33522A CALIBRATION and Keysight (Agilent) 33522A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33522A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33522A   Description / Specification:    
Keysight (Agilent) 33522A 30 MHz, 2 Ch Function / Arbitrary Waveform Generator

The Agilent 33522A is a 30 MHz synthesized waveform generator with built-in arbitrary waveform and pulse capabilities. It’s a combination of bench-top and system generator. With 16 standard waveforms, built-in 16-bit 250 MSa/s arbitrary waveform capability and precise pulse waveform capabilities with adjustable edge time makes this waveform generator a versatile solution for your testing requirements.
Specifications.

Maximum frequency: 30 MHz.
Number of channels: two.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option 002) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Burst, Output Gate.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Voltage Level (nom): 3 Vpp into open circuit, 1.5 Vpp into 50 Ω.
Output Impedance (nom): 50 Ω.
Two Channel Operating Modes: Independent, Coupled Parameter(s), Combined (Ch1+Ch2), Equal (Ch2 = Ch1), Differential (Ch2 = -Ch1).

Waveform Characteristics.
Sine.
Frequency Range: 1 μHz to 30 MHz, 1 μHz resolution.
Square and Pulse.
Frequency Range: 1 μHz to 30 MHz, 1 μHz resolution.
Rise and Fall Times (nom);
  Square: 8.4 ns, fixed.
  Pulse: 8.4 ns to 1 μs, independently variable, 100 ps or 3-digit resolution.
Ramp and Triangle.
Frequency Range: 1 μHz to 200 kHz, 1 μHz resolution.
Ramp Symmetry: 0.0% to 100.0%, 0.1% resolution (0% is negative ramp, 100% is positive ramp, 50% is triangle).
Gaussian Noise.
Bandwidth (typ): 1 mHz to 30 MHz, variable.
Crest Factor (nom): 4.6.
Repetition period: > 50 years.
Pseudorandom Binary Sequence.
Bit Rate: 1 mbps to 50 Mbps, 1 mbps resolution.
Sequence Length: 2^m-1, m=7, 9, 11, 15, 20, 23.

Options.
002 Increases Arbitrary Waveform memory from 1 MSa/channel to 16 MSa/channel.
010 High-stability frequency reference.
400 GPIB interface.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33522A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 33522A CALIBRATION and/or Keysight (Agilent) 33522A 30 MHz, 2 Ch Function / Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*