A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B1520A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   Keysight (Agilent) B1520A   Description / Specification:    
Keysight (Agilent) B1520A Multi-frequency capacitance measurement unit (MFCMU)

The Agilent B1520A Multi-frequency capacitance measurement unit (MFCMU) features AC impedance measurement (C-V, C-f, C-t). 1 kHz to 5 MHz frequency range with minimum 1 mHz frequency resolution. 25 V built-in DC bias and 100 V DC bias with SMU and SCUU (SMU CMU Unify Unit). It uses one slot in a B1500A Mainframe.
Specifications.

Measurement parameters: Cp-G, Cp-D, Cp-Q, Cp-Rp, Cs-Rs, Cs-D, Cs-Q, Lp-G, Lp-D, Lp-Q, Lp-Rp, Ls-Rs, Ls-D, Ls-Q, R-X, G-B, Z-q, Y-q.
Ranging: Auto and fixed.
Measurement terminal: Four-terminal pair configuration, four BNC (female) connectors.

Test signal.
Frequency:
  Range: 1 kHz to 5 MHz.
  Resolution: 1 mHz (minimum).
  Accuracy: ±0.008%.
Output signal level:
  Range: 10 mVrms to 250 mVrms.
  Resolution: 1 mVrms.
  Accuracy: ±(10.0% + 1 mVrms) at the measurement port of the MFCMU, ±(15.0% + 1 mVrms) at the measurement port of the MFCMU cable (1.5 m or 3.0 m).
Output impedance: 50 Ω, typical.

DC bias function.
DC bias:
  Range: 0 to ±25 V.
  Resolution: 1 mV.
  Accuracy: ±(0.5% + 5.0 mV) at the measurement port of the MFCMU or the MFCMU cable (1.5 m or 3.0 m)
Output impedance: 50 Ω, typical.
DC bias monitor:
  Range: 0 to ±25 V.
  Accuracy (open load): ±(0.2% of reading + 10.0 mV) at the measurement port of the MFCMU or the MFCMU cable (1.5 m or 3.0 m).



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) B1520A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) B1520A CALIBRATION and/or Keysight (Agilent) B1520A Multi-frequency capacitance measurement unit (MFCMU) REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: