Keysight (Agilent) E5281B CALIBRATION and Keysight (Agilent) E5281B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E5281B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) E5281B   Description / Specification:    
Keysight (Agilent) E5281B Medium Power Source/Measurement Unit (MPSMU)

The Agilent E5281B is a Medium Power Source/Measurement Unit (MPSMU) Source meter occupies one slot that works with the E5270B Parametric Measurement System Mainframe, 8-Slot. Source meter instruments are a type of electronic test equipment that measures and logs precise voltage and current data. Source meters collect information with high accuracy, ideal for current-voltage (I-V) characterization, semiconductor testing, and testing devices with both positive and negative current source values.
Specifications.

Measure resolution voltage range, resolution, and accuracy.
Range, Force resolution, High speed ADC, High resolution ADC, Force accuracy.
  ±0.5 V, 25 μV, 25 μV, 0.5 μV, ±(0.03 % + 350 μV).
  ±2 V, 100 μV, 100 μV, 2 μV, ±(0.03 % + 900 μV).
  ±5 V, 250 μV, 250 μV, 5 μV, ±(0.03 % + 2 mV).
  ±20 V, 1 mV, 1 mV, 20 μV, ±(0.03 % + 4 mV).
  ±40 V, 2 mV, 2 mV, 40 μV, ±(0.03 % + 7 mV).
  ±100 V, 5 mV, 5 mV, 100 μV, ±(0.04 % + 15 mV).

Measure accuracy voltage range, resolution, and accuracy.
Range, High speed ADC, High resolution ADC, Maximum current.
  ±0.5 V, ±(0.03 % + 250 μV), ±(0.02 % + 250 μV), 100 mA.
  ±2 V, ±(0.03 % + 700 μV), ±(0.02 % + 700 μV), 100 mA.
  ±5 V, ±(0.03 % + 2 mV), ±(0.02 % + 1 mV), 100 mA.
  ±20 V, ±(0.03 % + 4 mV), ±(0.02 % + 2 mV), 100 mA.
  ±40 V, ±(0.03 % + 8 mV), ±(0.02 % + 3 mV), 100 mA (Vo ≤ 20 V), 50 mA (20 V < Vo ≤ 40 V).
  ±100 V, ±(0.03 % + 20 mV), ±(0.03 % + 5 mV), 100 mA (Vo ≤ 20 V), 50 mA (20 V < Vo ≤ 40 V), 20 mA (40 V < Vo ≤ 100 V).

Current range, resolution, and accuracy.
Range, Force resolution, High speed ADC, High resolution ADC, Force accuracy, Measure accuracy, Max. voltage.
  ±1 nA, 50 fA, 50 fA, 10 fA, ±(0.5 %+3 pA+2 fA x Vo), ±(0.5 %+3 pA+2 fA x Vo), 100 V.
  ±10 nA, 500 fA, 500 fA, 10 fA, ±(0.5 %+7 pA+20 fA x Vo), ±(0.5 %+5 pA+20 fA x Vo), 100 V.
  ±100 nA, 5 pA, 5 pA, 100 fA, ±(0.12 %+50 pA+200 fA x Vo), ±(0.1 %+30 pA+200 fA x Vo), 100 V.
  ±1 μA, 50 pA, 50 pA, 1 pA, ±(0.12 %+400 pA+2 pA x Vo), ±(0.1 %+200 pA+2 pA x Vo), 100 V.
  ±10 μA, 500 pA, 500 pA, 10 pA, ±(0.12 %+5 nA+20 pA x Vo), ±(0.1 %+3 nA+20 pA x Vo), 100 V.
  ±100 μA, 5 nA, 5 nA, 100 pA, ±(0.12 %+40 nA+200 pA x Vo), ±(0.1 %+20 nA+200 pA x Vo), 100 V.
  ±1 mA, 50 nA, 50 nA, 1 nA, ±(0.12 %+500 nA+2 nA x Vo), ±(0.1 %+300 nA+2 nA x Vo), 100 V.
  ±10 mA, 500 nA, 500 nA, 10 nA, ±(0.12 %+4 μA+20 nA x Vo), ±(0.1 %+2 μA+20 nA x Vo), 100 V.
  ±100 mA, 5 μA, 5 μA, 100 nA, ±(0.12 %+50 μA+200 nA x Vo), ±(0.1 %+30 μA+200 nA x Vo), 100 mA (Vo ≤ 20 V), 50 mA (20 V < Vo ≤ 40 V), 20 mA (40 V < Vo ≤ 100 V).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) E5281B CALIBRATION and/or Keysight (Agilent) E5281B Medium Power Source/Measurement Unit (MPSMU) REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: