Keysight (Agilent) B2902A CALIBRATION and Keysight (Agilent) B2902A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B2902A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) B2902A   Description / Specification:    
Keysight (Agilent) B2902A 2 Ch Precision Source/Measure Unit

The Keysight / Agilent B2902A 2 Ch Precision Source/Measure Unit is a compact and cost-effective bench-top Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. These capabilities make the B2902A ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy.
Specifications.

Voltage source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max voltage.
  ±200 mV, 1 μV, ±(0.015 % + 225 μV), ≤ 10 μV, ±210 mV.
  ±2 V, 10 μV, ±(0.02 % + 350 μV), ≤ 20 μV, ±2.1 V.
  ±20 V, 100 μV, ±(0.015 % + 5 mV), ≤ 200 μV, ±21 V.
  ±200 V, 1 mV, ±(0.015 % + 50 mV), ≤ 2 mV, ±210 V.

Current source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max current.
  ±100 nA, 1 pA, ±(0.06 % + 100 pA), ≤ 2 pA, ±105 nA.
  ±1 μA, 10 pA, ±(0.025 % + 500 pA), ≤ 25 pA, ±1.05 μA.
  ±10 μA, 100 pA, ±(0.025 % + 1.5 nA), ≤ 60 pA, ±10.5 μA.
  ±100 μA, 1 nA, ±(0.02 % + 25 nA), ≤ 2 nA, ±105 μA.
  ±1 mA, 10 nA, ±(0.02 % + 200 nA), ≤ 6 nA, ±1.05 mA.
  ±10 mA, 100 nA, ±(0.02 % + 2.5 μA), ≤ 200 nA, ±10.5 mA.
  ±100 mA, 1 μA, ±(0.02 % + 20 μA), ≤ 600 nA, ±105 mA.
  ±1 A, 10 μA, ±(0.03 % + 1.5 mA), ≤ 70 μA, ±1.05 A.
  ±1.5 A, 10 μA, ±(0.05 % + 3.5 mA), ≤ 100 μA, ±1.515 A.
  ±3 A, 100 μA, ±(0.4 % + 7 mA), ≤ 120 μA, ±3.03 A.
  ±10 A pulse mode only, 100 μA, ±(0.4 % + 25 mA), , ±10.5 A.

Maximum current limitation
Ch1 voltage, Ch2 voltage, Max total current limitation of Ch1 and Ch2.
  ±(0 V < V ≤ 6 V), ±(0 V < V ≤ 6 V), Ch1 current + Ch2 current ≤ 4 A.
  ±(0 V < V ≤ 6 V), ±(6 V < V ≤ 21 V), Ch1 current + Ch2 current x 1.6 ≤ 4 A.
  ±(6 V < V ≤ 21 V), ±(0 V < V ≤ 6 V), Ch1 current + Ch2 current x 0.625 ≤ 2.5 A.
  ±(6 V < V ≤ 21 V), ±(6 V < V ≤ 21 V), Ch1 current + Ch2 current ≤ 2.5 A.



 

Standard Calibration $750.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) B2902A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) B2902A CALIBRATION and/or Keysight (Agilent) B2902A 2 Ch Precision Source/Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: