Keysight (Agilent) B2902A CALIBRATION and Keysight (Agilent) B2902A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B2902A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) B2902A   Description / Specification:    
Keysight (Agilent) B2902A 2 Ch Precision Source/Measure Unit

The Keysight / Agilent B2902A 2 Ch Precision Source/Measure Unit is a compact and cost-effective bench-top Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. These capabilities make the B2902A ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy.
Specifications.

Voltage source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max voltage.
  ±200 mV, 1 μV, ±(0.015 % + 225 μV), ≤ 10 μV, ±210 mV.
  ±2 V, 10 μV, ±(0.02 % + 350 μV), ≤ 20 μV, ±2.1 V.
  ±20 V, 100 μV, ±(0.015 % + 5 mV), ≤ 200 μV, ±21 V.
  ±200 V, 1 mV, ±(0.015 % + 50 mV), ≤ 2 mV, ±210 V.

Current source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max current.
  ±100 nA, 1 pA, ±(0.06 % + 100 pA), ≤ 2 pA, ±105 nA.
  ±1 μA, 10 pA, ±(0.025 % + 500 pA), ≤ 25 pA, ±1.05 μA.
  ±10 μA, 100 pA, ±(0.025 % + 1.5 nA), ≤ 60 pA, ±10.5 μA.
  ±100 μA, 1 nA, ±(0.02 % + 25 nA), ≤ 2 nA, ±105 μA.
  ±1 mA, 10 nA, ±(0.02 % + 200 nA), ≤ 6 nA, ±1.05 mA.
  ±10 mA, 100 nA, ±(0.02 % + 2.5 μA), ≤ 200 nA, ±10.5 mA.
  ±100 mA, 1 μA, ±(0.02 % + 20 μA), ≤ 600 nA, ±105 mA.
  ±1 A, 10 μA, ±(0.03 % + 1.5 mA), ≤ 70 μA, ±1.05 A.
  ±1.5 A, 10 μA, ±(0.05 % + 3.5 mA), ≤ 100 μA, ±1.515 A.
  ±3 A, 100 μA, ±(0.4 % + 7 mA), ≤ 120 μA, ±3.03 A.
  ±10 A pulse mode only, 100 μA, ±(0.4 % + 25 mA), , ±10.5 A.

Maximum current limitation
Ch1 voltage, Ch2 voltage, Max total current limitation of Ch1 and Ch2.
  ±(0 V < V ≤ 6 V), ±(0 V < V ≤ 6 V), Ch1 current + Ch2 current ≤ 4 A.
  ±(0 V < V ≤ 6 V), ±(6 V < V ≤ 21 V), Ch1 current + Ch2 current x 1.6 ≤ 4 A.
  ±(6 V < V ≤ 21 V), ±(0 V < V ≤ 6 V), Ch1 current + Ch2 current x 0.625 ≤ 2.5 A.
  ±(6 V < V ≤ 21 V), ±(6 V < V ≤ 21 V), Ch1 current + Ch2 current ≤ 2.5 A.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) B2902A CALIBRATION and/or Keysight (Agilent) B2902A 2 Ch Precision Source/Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?