Keysight (Agilent) B1510A CALIBRATION and Keysight (Agilent) B1510A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B1510A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Semiconductor Tester?
Shop for Comparable Products on our
 used Semiconductor Tester page

 
   Keysight (Agilent) B1510A   Description / Specification:    
Keysight (Agilent) B1510A High power source/monitor Unit (HPSMU)

The Agilent B1510A High power source/monitor unit (HPSMU) features range up to 200 V/1 A with 4-quadrant operation. Minimum measurement resolution 10 fA/2 μV. It uses two slots in a B1500A Mainframe.
Specifications.

Voltage (high resolution ADC)
.
Range, Force resolution, Measure resolution, Force accuracy ±(% read value + offset voltage V), Measure accuracy (% read value + offset voltage V), Maximum current .
  ±2 V, 100 μV, 2 μV, ±(0.018% + 400 μV), ±(0.01% + 140 μV), 1 A.
  ±20 V, 1 mV, 20 μV, ±(0.018% + 3 mV), ±(0.009% + 900 μV), 1 A. 
  ±40 V, 2 mV, 40 μV, ±(0.018% + 6 mV), ±(0.01% + 1 mV), 500 mA.
  ±100 V, 5 mV, 100 μV, ±(0.018% + 15 mV), ±(0.012% + 2.5 mV), 125 mA.
  ±200 V, 10 mV, 200 μV, ±(0.018% + 30 mV), ±(0.014% + 2.8 mV), 50 mA.

Current (high resolution ADC).
Range, Force resolution, Measure resolution, Force accuracy ±(% + A + A), Measure accuracy (% + A + A), Max voltage.
  ±1 nA, 50 fA, 10 fA, ±(0.1%+300 fA+1 fA x Vo), ±(0.1%+200 fA+1 fA x Vo), 200 V.
  ±10 nA, 500 fA, 10 fA, ±(0.1%+3 pA+10 fA x Vo), ±(0.1%+1 pA+10 fA x Vo), 200 V.
  ±100 nA, 5 pA, 100 fA, ±(0.05%+30 pA+100 fA x Vo), ±(0.05%+20 pA+100 fA x Vo), 200 V.
  ±1 μA, 50 pA, 1 pA, ±(0.05%+300 pA+1 pA x Vo), ±(0.05%+100 pA+1 pA x Vo), 200 V.
  ±10 μA, 500 pA, 10 pA, ±(0.05%+3 nA+10 pA x Vo), ±(0.04%+2 nA+10 pA x Vo), 200 V.
  ±100 μA, 5 nA, 100 pA, ±(0.035%+15 nA+100 pA x Vo), ±(0.03%+3 nA+100 pA x Vo), 200 V.
  ±1 mA, 50 nA, 1 nA, ±(0.04%+150 nA+1 nA x Vo), ±(0.03%+60 nA+1 nA x Vo), 200 V.
  ±10 mA, 500 nA, 10 nA, ±(0.04%+1.5 μA+10 nA x Vo), ±(0.03%+200 nA+10 nA x Vo), 200 V.
  ±100 mA, 5 μA, 100 nA, ±(0.045%+15 μA+100 nA x Vo), ±(0.04%+6 μA+100 nA x Vo), 200 V (Io ≤ 50 mA)/ 100 V (50 mA < Io ≤ 125 mA)/ 40 V (125 mA < Io ≤ 500 mA)/ 20 V (500 mA < Io ≤ 1 A).
  ±1 A, 50 μA, 1 μA, ±(0.4%+300 μA+1 μA x Vo), ±(0.4%+150 μA+1 μA x Vo), 200 V (Io ≤ 50 mA)/ 100 V (50 mA < Io ≤ 125 mA)/ 40 V (125 mA < Io ≤ 500 mA)/ 20 V (500 mA < Io ≤ 1 A).

Power consumption.
Voltage source mode (Ic is the current compliance setting):
  20 x Ic (W) (2 to 20V),
  40 x Ic (W) (40V),
  100 x Ic (W) (100V),
  200 x Ic (W) (200V).
Current source mode (Vc is the voltage compliance setting and Io is output current):
  20 x Io (W) (Vc ≤ 20),
  40 x Io (W) (20 < Vc ≤ 40),
  100 x Io (W) (40 < Vc ≤ 100),
  200 x Io (W) (100 < Vc ≤ 200).



 

Standard Calibration $520.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) B1510A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your Keysight (Agilent) B1510A CALIBRATION and/or Keysight (Agilent) B1510A High power source/monitor Unit (HPSMU) REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: