Keysight (Agilent) 53150A REPAIR and Keysight (Agilent) 53150A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 53150A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53150A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53150A   Description / Specification:    
Keysight (Agilent) 53150A CW Microwave Counter with Power Measurement

The Agilent 53150A CW Microwave Counter with Power Measurement offers an uncluttered, feature laden front panel. These designs present no-compromise performance and quality in a surprisingly small, light, battery operated product. If AC power is unavailable, the internal, replaceable camcorder batteries provide at least 2.5 hours of continuous operation. The unit can also be powered from an external 11-18 Vdc source. Input Characteristics. Channel 1. Frequency Range (1 M-Ohm): 10 Hz to125 MHz. Resolution: Selectable 1 Hz to 1 MHz. Connector: BNC female. Low Pass Filter: 50 kHz, selectable. Channel 2. Frequency Range (50 Ohm): 0.05 to 20 GHz. Resolution: Selectable 1 Hz to 1 MHz. Acquisition Time: 100 ms to 140 ms. Gate Time: 1/Resolution. FM Tolerance: 20 MHz p-p max. @ 10 MHz rate to 26.5 GHz; 12 MHz p-p max. @ 10 MHz rate to 46 GHz. AM Tolerance: Any depth/rate within dynamic range of input. Amplitude Discrimination (above 250 MHz): 20 dB typ. for greater than 75 MHz separation; 10 dB typ. for less than 75 MHz separation. Connector: 3.5 mm SMA compatible. Power Measurement. Range: Counter sensitivity to +7 dBm. Units: dBm or milliwatts/microwatts. Resolution: 0.01 dB. Display: Backlit LCD. Sample Rate: User-selectable Fast, Medium, Slow or Hold. Options. Opt 001: Oven Timebase. Opt 002: Battery/DC Input.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53150A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 53150A REPAIR and/or Keysight (Agilent) 53150A CW Microwave Counter with Power Measurement CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: