Keysight (Agilent) 53152A CALIBRATION and Keysight (Agilent) 53152A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53152A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53152A   Description / Specification:    
Keysight (Agilent) 53152A CW Microwave Counter with Power Measurement

The Agilent 53152A CW Microwave Counter with Power Measurement offers an uncluttered, feature laden front panel. These designs present no-compromise performance and quality in a surprisingly small, light, battery operated product. If AC power is unavailable, the internal, replaceable camcorder batteries provide at least 2.5 hours of continuous operation. The unit can also be powered from an external 11-18 Vdc source. Input Characteristics. Channel 1. Frequency Range (1 M-Ohm): 10 Hz to125 MHz. Resolution: Selectable 1 Hz to 1 MHz. Connector: BNC female. Low Pass Filter: 50 kHz, selectable. Channel 2. Frequency Range (50 Ohm): 0.05 to 46GHz. Resolution: Selectable 1 Hz to 1 MHz. Acquisition Time: 100 ms to 140 ms. Gate Time: 1/Resolution. FM Tolerance: 20 MHz p-p max. @ 10 MHz rate to 26.5 GHz; 12 MHz p-p max. @ 10 MHz rate to 46 GHz. AM Tolerance: Any depth/rate within dynamic range of input. Amplitude Discrimination (above 250 MHz): 20 dB typ. for greater than 75 MHz separation; 10 dB typ. for less than 75 MHz separation. Connector: 2.92 mm Planar Crown. Power Measurement. Range: Counter sensitivity to +7 dBm. Units: dBm or milliwatts/microwatts. Resolution: 0.01 dB. Display: Backlit LCD. Sample Rate: User-selectable Fast, Medium, Slow or Hold. Options. Opt 001: Oven Timebase. Opt 002: Battery/DC Input.



 

Standard Calibration $470.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53152A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 53152A CALIBRATION and/or Keysight (Agilent) 53152A CW Microwave Counter with Power Measurement REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: