Keysight (Agilent) 5316A CALIBRATION and Keysight (Agilent) 5316A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 5316A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 5316A   Description / Specification:    
Keysight (Agilent) 5316A Universal Counter

The HP 5316A is a Universal Counter, measuring signals over a range of DC to 100 MHz. The HP 5316A offers the measurement capabilities of the HP 5315A in a rack-and-stack metal case, built-in HP-IB capabilities, and front -panel access to Channel A and B trigger levels for easy measurement with a DVM. The 5316A measures frequency, period, time interval, time interval average, time interval holdoff (delay), and Ratio. A Totalize function with manual or external gating is also provided. All measurements except Totalize are displayed in engineering notation with up to eight digits of resolution. In addition, the 5316A may be programmed via the HP -IB. Two independent input channels are provided for time interval measurements. Each input channel has an Attenuator (X1, X20), Trigger Slope selector, Trigger Level/Sensitivity control, three state trigger lamps, and front panel Trigger Level Monitoring jacks. A front panel selectable Low-Pass Filter is provided for Channel A. Channel A and B impedance is 1 M-Ohm/40pF and accuracy is ± Resolution ± (time base error) * frequency. Options. Opt 001: High-stability timebase (TCXO). Opt 003: C Channel, Input range: 50 to 1000 MHz, prescaled by 10. Opt 004: High-stability oven timebase.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 5316A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 5316A CALIBRATION and/or Keysight (Agilent) 5316A Universal Counter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: