Keysight (Agilent) 53181A REPAIR and Keysight (Agilent) 53181A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 53181A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 53181A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Frequency Counter? Shop for Comparable Products on our   new Frequency Counter page

 
   Keysight (Agilent) 53181A   Description / Specification:    
Keysight (Agilent) 53181A RF Frequency Counter

The HP 53181A RF counter employs continuous measurement technology to provide superior performance at a very low price. Frequency and period measurements are provided over the range of 0.1 Hz to 225 MHz with exceptional resolution of 10 digits in one second. An optional second channel increases the frequency range to 1.5 GHz, 3 GHz, 5 GHz, or 12.4 GHz, making it easy to cover your exact RF measurement needs. Other features of the HP 53181A include HP-IB, automatic limit testing, analog display mode, single-button recall, extensive in-box statistical and math analysis, and more. Specification & Characteristics. Measurements: Frequency, frequency ratio (with optional CH 2), period, peak voltage. Analysis: Automatic limit testing, math (scale and offset, statistics (minimum, maximum,Mean, standard deviation). Statistics available on all measurements or only measurements that fall within limits. Frequency range CH 1: dc to 225 MHz. Frequency resolution: 10 digits/s. Measurement speed: Up to 200 meas/s. Input conditioning: (Selectable on CH 1). Impedance, coupling: 1 M-ohm or 50 ohm, ac or dc. Low pass filter: 100 kHz, switchable. Attenuation: x1 or x10. External timebase reference input: 1, 5, 10 MHz. Trigger: Trigger on rising/falling edge; set level by percent of signal level or absolute voltage; set sensitivity to LOW, MED, or HIGH. Gating and arming: Auto, manual (set gate time or number of digits of resolution); external, delay. Interfaces: Standard HP-IB (IEEE 488.1 and 488.2) with SCPI-compatable language; talk only RS-232. Options. Opt 001, Medium-Stability Timebase. Opt 002, DC Power Input. Opt 010, High-Stability Timebase. Opt 015, 1.5 GHz Ch. w/BNC Connector. Opt 030, 3 GHz Channel with BNC Connector. Opt 050, 5 GHz Channel with Type-N Connector. Opt 124, 12.4 GHz Channel with Type-N Connector. Opt 060, Rear-Panel Connectors.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 53181A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 53181A REPAIR and/or Keysight (Agilent) 53181A RF Frequency Counter CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: