Keysight (Agilent) 54520A REPAIR and Keysight (Agilent) 54520A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54520A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54520A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54520A   Description / Specification:    
Keysight (Agilent) 54520A 2 Ch 250 MHz Digitizing Oscilloscope

The HP 54520A is a 250 MHz, 1 GSa/s sample rate, 2-channel digitizing oscilloscope. It has all of the features that you would expect in a scope plus more. Use sequential single-shot when you need to capture success ive single-shot events without capturing the dead time in between. It is a great tool for applications such as pulsed laser research, high-energy physics, and pulse echo. Use glitch trigger to find the causes of anomalies in circuit operation. Trigger on hard-to-see narrow glitches down to 1 ns wide. Waveforms can be saved and time-stamped upon failure of either wave form compare or limit test. Up to 665 failures of 500 points each can be stored in multiple memory and sent to a printer, plotter, or a computer via HP-IB. Specifications. Repetitive Bandwidth: 500 MHz (equivalent time). Real-time bandwidth: 250 MHz (1 channel on), 125 MHz (2 channels on). Number of channels (all are simultaneous acquisition): 2. Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical dc gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits (10 bits via HP-IB with averaging). Maximum sample rate (Real time mode): 1 GSa/s (1 channel on), 500 MSa/s (2 channels on). Maximum sample rate (Repetitive mode): 1 GSa/s. Waveform record length: 32,768 points (real-time), 501 points (repetitive). Maximum input: 1 M-ohm: ± 250 V (dc + ac) [ac<10 kHz], 50 ohm: 5 V rms. Time base range: 500 ps/div to 5 s/div. Resolution: 10 ps. Trigger Pulse width (minimum) 1 ns. Monochrome Display. Opt 001 Telecommunications Mask Test Software.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54520A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 54520A REPAIR and/or Keysight (Agilent) 54520A 2 Ch 250 MHz Digitizing Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: