Keysight (Agilent) 54600A REPAIR and Keysight (Agilent) 54600A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54600A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54600A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54600A   Description / Specification:    
Keysight (Agilent) 54600A 2 Ch 100 MHz Digital Oscilloscope

The HP 54600A two-channel oscilloscope provides powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. It captures repetitive signals at up to 10 GSa/sec (single shot phenomena at up to 20 MSa/sec) giving a clear and accurate display of the most troublesome signals. The display update rate of over one million points per second provides a display with unprecedented interactivity. Specifications. Bandwidth ( -3dB): dc to 100 MHz. Channels: 2. Input voltage ranges: 2 mV/div to 5 V/div. Accuracy: ± 1.5%. Vernier accuracy: Fully calibrated ± 3%. Rise time <3.5 ns (calculated). Coupling: dc. ac, and ground. Maximum input: 400 V (dc + peak ac). Sweep speeds, main and delayed: 5 s/div to 2 ns/div/1 ns/div. Accuracy: ± 0.01%. Resolution: 100 ps. Vernier accuracy: ± 0.05%. Trigger Sensitivity all channels: dc to 25 MHz, 0.35 div or 3.5 mV. Max sample rate: 10/GSa/s for repetitive signals, 20 MSa/s single shot. Record length: 4,000 points (2,000 points single shot). Max update rate: 1,000,000 points/s.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54600A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 54600A REPAIR and/or Keysight (Agilent) 54600A 2 Ch 100 MHz Digital Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: