Keysight (Agilent) 54600B CALIBRATION and Keysight (Agilent) 54600B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54600B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54600B   Description / Specification:    
Keysight (Agilent) 54600B 2 Ch 100 MHz Digital Oscilloscope

The HP 54600B two-channel oscilloscope provides powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. It captures repetitive signals at up to 10 GSa/sec (single shot phenomena at up to 20 MSa/sec) giving a clear and accurate display of the most troublesome signals. The display update rate of over one and a half million points per second provides a display with unprecedented interactivity. Bright, crisp displays for the most demanding signals at all sweep speeds and delayed sweep magnifications. Storage for glitch and transient analys is is as simple as pressing a button. Pretrigger viewing lets you view even ts that an analog scope would miss. Specifications. Bandwidth: dc to 100 MHz. Channels: 2. Sensitivity (per division): 2 mV/div to 5 V/div. Accuracy: ± 1.5%. Vernier accuracy: ± 3%. Rise time <3.5 ns (calculated). Input R & C: 1 M-ohm, = 13 pf. Maximum input dc + peak ac: 400 V. Sweep speed: 5 s/div to 2 ns/div. Accuracy: ± 0.01%. Resolution: 100 ps. Vernier accuracy: ± 0.05%. Max sample rate: 20 MSa/s. Record length (pts vectors off/on): 4,000/2,000. Trigger Sensitivity all channels: dc to 25 MHz, 0.35 div or 3.5 mV.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54600B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 54600B CALIBRATION and/or Keysight (Agilent) 54600B 2 Ch 100 MHz Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: