Keysight (Agilent) 54603B REPAIR and Keysight (Agilent) 54603B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54603B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54603B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54603B   Description / Specification:    
Keysight (Agilent) 54603B 2 Ch 60 MHz Digital Oscilloscope

The HP 54603B two-channel oscilloscope provides powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. It captures repetitive signals at up to 10 GSa/sec (single shot phenomena at up to 20 MSa/sec) giving a clear and accurate display of the most troublesome signals. The display update rate of over one and a half million points per second provides a display with unprecedented interactivity. Bright, crisp displays for the most demanding signals at all sweep speeds and delayed sweep magnifications. Storage for glitch and transient analys is is as simple as pressing a button. Pretrigger viewing lets you view even ts that an analog scope would miss. Specifications. Bandwidth: dc to 60 MHz. Channels: 2. Sensitivity (per division): 2 mV/div to 5 V/div. Accuracy: ± 2%. Vernier accuracy: ± 3.5%. Rise time 5.8 ns (calculated). Input R & C: 1 M-ohm, = 13 pf. Maximum input dc + peak ac: 400 V. Sweep speed: 5 s/div to 2 ns/div. Accuracy: ± 0.01%. Resolution: 100 ps. Vernier accuracy: ± 0.05%. Max sample rate: 20 MSa/s. Record length (pts vectors off/on): 4,000/2,000. Trigger Sensitivity all channels: dc to 25 MHz, 0.35 div or 3.5 mV.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54603B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 54603B REPAIR and/or Keysight (Agilent) 54603B 2 Ch 60 MHz Digital Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: