Keysight (Agilent) 54621A CALIBRATION and Keysight (Agilent) 54621A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54621A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54621A   Description / Specification:    
Keysight (Agilent) 54621A 2 Ch 60 MHz MegaZoom Oscilloscope

The Agilent 54621A Portable Oscilloscope has a bandwidth of 60 MHz, MegaZoom deep memory technology, advanced triggering, a high definition display, the look and feel of an analog scope, and built-in help, Agilent’s 54621A gives you a view into your system performance that is unmatched by any other portable digital signal analyzer (DSO). MegaZoom technology gives you higher sampling speeds where you need them to observe the wide range of signals in your system rather than just the faster few sweep speeds. MegaZoom is available at all times and does not require a special operating mode. Measurement data are mapped into a high-resolution screen with 32 levels of intensity and 1000 points resolution, nearly twice the display standard. Now glitches are more clearly identifiable. Specifications. Channels: 2. Bandwidth: 60 MHz. Max Sample Rate: 200 MSa/s. Max Input: 400 V dc + peak ac. Resolution: 8 bits. High Resolution Mode: 12 bits when >200 us/div average mode. Range: 1 mV to 5 V. Max Memory: 4 M. TimeBase: 5 ns/div to 50 s/div. Peak Detection: 5 ns. Triggering Source: Internal selection of CH1, CH2 and External. Triggering Modes Edge, pattern, pulse width, TV, sequence, and serial propocals of CAN, I^2C, LIN, SPI, & USB. Display: High definition monochrome with 32 shades of gray and 1,000 points horizontal resolution. Measurements Automatic: Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, undershoot, RMS, frequency, period, + width, – width, duty cycle, time at max, time at min, phase, and delay. Counter: Build-in 5 digit frequency counter on any channel, counts up to 125 MHz. Math Functions CH1 – CH2, CH1 + CH2, 1*2, FFT, Differentiate, Integrate. Option 003, Shielding Option for use in severe environments or with sensitive devices under test.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54621A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 54621A CALIBRATION and/or Keysight (Agilent) 54621A 2 Ch 60 MHz MegaZoom Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: