Keysight (Agilent) 54641A CALIBRATION and Keysight (Agilent) 54641A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54641A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54641A   Description / Specification:    
Keysight (Agilent) 54641A 2 Ch 350 MHz MegaZoom Oscilloscope

The Agilent 54641A Portable Oscilloscope has a bandwidth of 350 MHz, MegaZoom deep memory technology, advanced triggering, a high definition display, the look and feel of an analog scope, and built-in help, Agilent’s 54641A gives you a view into your system performance that is unmatched by any other portable digital signal analyzer (DSO). MegaZoom technology gives you higher sampling speeds where you need them to observe the wide range of signals in your system rather than just the faster few sweep speeds. MegaZoom is available at all times and does not require a special operating mode. Measurement data are mapped into a high-resolution screen with 32 levels of intensity and 1000 points resolution, nearly twice the display standard. Now glitches are more clearly identifiable. Specifications. Channels: 2. Bandwidth: 350 MHz. Max Sample Rate: 2 GSa/s. Max Input: 400 V dc + peak ac. Resolution: 8 bits. High Resolution Mode: 12 bits when >200 us/div average mode. Range: 1 mV to 5 V. Max Memory: 8 M. TimeBase: 5 ns/div to 50 s/div. Peak Detection: 5 ns. Triggering Source: Internal selection of CH1, CH2, (3 & 4) and External. Triggering Modes Edge, pattern, pulse width, TV, sequence, and serial propocals of CAN, I^2C, LIN, SPI, & USB. Display: High definition monochrome with 32 shades of gray and 1,000 points horizontal resolution. Measurements Automatic: Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, undershoot, RMS, frequency, period, + width, – width, duty cycle, time at max, time at min, phase, and delay. Counter: Build-in 5 digit frequency counter on any channel, counts up to 125 MHz. Math Functions CH1 – CH2, CH1 + CH2, 1*2, FFT, Differentiate, Integrate.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54641A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 54641A CALIBRATION and/or Keysight (Agilent) 54641A 2 Ch 350 MHz MegaZoom Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: