Keysight (Agilent) 54751A REPAIR and Keysight (Agilent) 54751A CALIBRATION

The Keysight (Agilent) 54751A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54751A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54751A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 54751A   Description / Specification:    
Keysight (Agilent) 54751A 2 Ch 20GHz Vertical Plug-in Module

The Agilent 54751A plug-in offers two 20 GHz bandwidth channels. The two-wide configuration allows up to four channels in the HP 54750A mainframe. The bandwidth of each channel may be selected independently from the channel menu as either 20 GHz or 12.4 GHz. The bandwidth of the channel is altered by changing the bias on the sampling bridge. The low-noise characteristic of the plug-in gives an RMS noise level of < 1.0 mV in the high-bandwidth mode and < 0.5 mV in the low-bandwidth mode. With exceptionally low noise and a minimum sensitivity of 1 mV/div, the HP 54751A is ideally suited for evaluation of low-level signals. The plug-in provides a single external trigger input of 2.5 GHz or 12 GHz bandwidth. Triggering to 18 GHz is possible by using the HP 54118A. Specifications with 54750A. DC-coupled bandwidth (–3dB): High bandwidth Channel 1 & 2, 20 GHz. DC-coupled bandwidth (–3dB): Low bandwidth Channel 1 & 2, 12.4 GHz. Rise time (calculated): High bandwidth Channel 1 & 2, <= 17.5 ps. Rise time (calculated): Low bandwidth Channel 1 & 2, <= 28.2 ps. Noise (RMS) High bw: <= 1 mV. Noise (RMS) Low bw: <= 0.5 mV. DC accuracy (single voltage marker): 0.4% of full-scale or marker reading (whichever is greater) ± 2 mV ± 1.2% of (reading-channel offset). Dynamic range: ± 400 mV relative to channel offset. Connectors: 3.5 mm.



 

Standard Calibration $440.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54751A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 54751A REPAIR and/or Keysight (Agilent) 54751A 2 Ch 20GHz Vertical Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: