Keysight (Agilent) 54754A REPAIR and Keysight (Agilent) 54754A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54754A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54754A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   Keysight (Agilent) 54754A   Description / Specification:    
Keysight (Agilent) 54754A 2 Ch Differential TDR Plug-in Module

The HP 54754A 2 Ch Differential TDR Plug-in Module has two independent vertical channels and two step generators it is used with 86100 Infiniium DCA. The bandwidth of both channels is 18 GHz. The step generators may be operated singly, simultaneously but independently, differentially, or as common-mode stimulus. The TDR results may be viewed as common mode or differentially and displayed simultaneously. Once selected, the display mode is computed automatically, freeing the user from setting up mathematical functions. Each step may be skewed separately in time. Coupled with the ability to skew the vertical channels, it is possible to accurately perform differential TDR when the launch cables are not the same electrical length. Specifications. Electrical Channel Bandwidth:12.4 and 18 GHz. Transition Time (10% to 90%, calculated from TR = 0.35/BW): 28.2 ps (12.4 GHz); 19.4 ps (18 GHz). RMS Noise Characteristic 0.25 mV (12.4 GHz); 0.5 mV (18 GHz). RMS Noise Maximum 0.5 mv (12.4 GHz); 1 mV (18 GHz). Scale Factor Minimum: 1 mV/division. Scale Factor Maximum: 100 mV/division. DC Accuracy (single marker): ±0.4% of full scale or marker reading (whichever is greater) ±2 mV ±1.2% of (reading-channel offset). CW Offset Range (referenced from center of screen): ±500 mV. Input Dynamic Range (relative to channel offset): ±400 mV. Maximum Input Signal: ±2 V (+16 dBm). Nominal Impedance: 50 ohm. Reflections (for 30 ps rise time): 5%. Electrical Input: 3.5 mm (male).



 

Standard Calibration $750.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54754A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 54754A REPAIR and/or Keysight (Agilent) 54754A 2 Ch Differential TDR Plug-in Module CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: