Keysight (Agilent) 60504A CALIBRATION and Keysight (Agilent) 60504A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 60504A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 60504A   Description / Specification:    
Keysight (Agilent) 60504A 120 A, 600 W DC Electronic Load Module

The HP 60504A 600 Watt Single Input Load Module is used in applications such as over-voltage protection testing for power supplies, zero volt load simulation for testing batteries, and power pulse generation for testing power components require power supplies in the test system configuration. Specifications. DC input ratings: 0-120A, 3-60V, (current derated from 0-3V) power limited to 600W. Modes: constant current (CC), constant voltage (CV), and constant resistance (CR). Programmable ranges: CC mode: 0-12A, 0-1 20A / CR mode: 0.017-0.5 ohm, 0.5-500 ohm, 5-5000 ohm. Programming accuracy: ± 0.12% ± 130 mA (in 120A CC range). Programming resolution: 32 mA (in 120 A CC range). Programmable electronic short: 0.017 ohm (0.012 ohm typical). Readback resolution: 32 mA, 16 mV. Readback accuracy: 0.1% ± 110 mA, 0.1% ± 45 mV. Built-in pulse waveform generation: Frequency 0.25 Hz to 10kHz, Duty cycle 6 to 94%, Slew rate 2 A/ ms-10 A / us in 120A CC range. Analog programming: 0 to 10 V. Analog programming bandwidth: 10 kHz in CC mode.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 60504A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 60504A CALIBRATION and/or Keysight (Agilent) 60504A 120 A, 600 W DC Electronic Load Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: