Keysight (Agilent) 60507B CALIBRATION and Keysight (Agilent) 60507B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 60507B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   Keysight (Agilent) 60507B   Description / Specification:    
Keysight (Agilent) 60507B 60 A, 500 W DC Electronic Load Module

The HP 60507B dc electronic load is optimized to address a broad range of dynamic loading applications. They are specifically designed for stability in applications where fast transients are applied to the load inputs, such as during dc power supply startup characterization or transient response testing. Dynamic load performance can be further tailored to specific application needs with the programmable slew rate feature. The HP 60507B meets all specifications when operated above 3.0 V; however, the dc operating characteristics also extend below this minimum-input voltage for static tests. Because of the FET technology used in the power input circuits, HP electronic loads have a low minimum-input resistance allowing them to sink high currents even at low voltages. Specifications. Amperes: 0 to 60 A. Volts: 3 to 150 V. Maximum power (at 40° C): 500 W. Constant current mode Ranges: 0 to 6 A, 0 to 60 A. Constant current mode Accuracy: 0.1% ±80 mA. Constant current mode Regulation: 10 mA (w/ >=3 V at the point). Constant voltage mode Accuracy 0.1% ±125 mV. Constant voltage mode Regulation (w/remote sense): 10 mV. Constant resistance mode Ranges: 0.033 to 2.5 ohm, 2.5 to 2,500 ohms, 25 to 10,000 ohms. Transient generator Frequency range: 0.25 Hz to 10 kHz (3% Accuracy). Current readback accuracy: 0.1% ±65 mA. Power readback accuracy: 0.2% ±8 W. Ripple and noise (20-Hz to 10-MHz noise): 4 mA rms, 40 mA peak-to-peak (Current), 10 mV rms (Voltage).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 60507B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) 60507B CALIBRATION and/or Keysight (Agilent) 60507B 60 A, 500 W DC Electronic Load Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: