Keysight (Agilent) 66102A CALIBRATION and Keysight (Agilent) 66102A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 66102A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 66102A   Description / Specification:    
Keysight (Agilent) 66102A 20V 7.5A Single Output DC Power Module

The Agilent 66102A DC Power Plug-in Module's output is designed for automated testing that helps meet changing requirements in ATE and production test with a modular design that conserves rack space and simplifies system cabling and assembly. The Agilent 66102A is used with the 66000A mainframe. Specifications. Output voltage: 0 to 20 V. Output current: 0 to 7.5 A. Maximum power: 150 W. Programming accuracy at 25 °C ± 5 °C: Voltage 0.03% + 8 mV, Current 0.03% + 3 mA. Readback accuracy (via GPIB or keyboard display at 25 °C ± 5 °C): Voltage 0.02% + 5 mV, Current 0.02% + 3 mA. Ripple and noise from 20 Hz to 20 MHz Constant voltage: rms 3 mV, peak-to-peak 7 mV. Ripple and noise from 20 Hz to 20 MHz Constant current: rms 4 mA. Line regulation: Voltage 0.5 mV, Current 0.5 mA. Load regulation: Voltage 1 mV, Current 0.2 mA. Transient response time: Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of the power module rated output current. OVP accuracy (characteristic): 250 mV. Options. Opt 760, Adds isolation/polarity relays. Opt J17, External monitor.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 66102A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 66102A CALIBRATION and/or Keysight (Agilent) 66102A 20V 7.5A Single Output DC Power Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: