Keysight (Agilent) 6643A CALIBRATION and Keysight (Agilent) 6643A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 6643A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   Keysight (Agilent) 6643A   Description / Specification:    
Keysight (Agilent) 6643A 35V 6A Single Output System DC Power Supply

The Agilent 6643A Single-Output DC System Power Supply (GPIB) offers fast, low-noise outputs; built-in measurements and advanced programmable features; and protection features to ensure DUT safety. Specifications. DC Output: 0 to 35 V / 0 to 6 A (40° C). Programming Accuracy at 25° C ±5° C (Voltage / Current): 0.06% + 15 mV / 0.15% + 6.7 mA. Ripple and Noise (20 Hz to 20 MHz); Voltage rms: 400 µV. peak-to-peak: 4 mV. Current rms: 3 mA. Readback accuracy at 25° C ±5° C (percent of reading plus fixed): Voltage 0.07% + 25 mV, +Current 0.15% + 5 mA, –Current 0.35% + 12 mA. Load regulation: Voltage 3 mV, Current 0.25 mA. Line regulation: Voltage 1 mV, Current 0.25 mA. Transient Response Time: Less than 100 µs for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply, or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current. Supplemental characteristics. dc Floating Voltage: Output terminals can be floated up to ±240 Vdc from chassis ground. Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB. Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Down Programming: An active down programmer sinks approximately 20% of the rated output current. Modulation: (Analog programming of output voltage and current). Input Signal: 0 to –5V. Input Impedance: 10 k Ohm nominal. ac Input: (ac input frequency 47 to 63).



 

Standard Calibration $145.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 6643A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) 6643A CALIBRATION and/or Keysight (Agilent) 6643A 35V 6A Single Output System DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: