Keysight (Agilent) 70820A REPAIR and Keysight (Agilent) 70820A CALIBRATION

The Keysight (Agilent) 70820A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 70820A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 70820A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer Component?
Shop for Comparable Products on our
 used Network Analyzer Component page

 
   Keysight (Agilent) 70820A   Description / Specification:    
Keysight (Agilent) 70820A Microwave Transition Analyzer, MMS

The HP 70820A Microwave Transition Analyzer for 70000 Modular Measurement System (MMS), 4/8-width module has two identical signal processing channels. Each channel samples and digitizes signals over an input bandwidth of dc to 40 GHz. The channels are sampled simultaneously (within 10 ps), permitting accurate ratioed amplitude and phase measurements. A single synthesized low-noise oscillator drives a step recovery diode, the output of which is split into two pulse trains that drive the microwave samplers. The microwave samplers and the analog-to-digital converters (ADCs) are run at the same frequency. The maximum sampling frequency is 20 MSa/s (20 million samples per second). Specifications. Operating input range: <10 dBm (±320 mV, dc +ac peak, includes the dc offset). Maximum safe input: 16 dBm peak (±2 V pk-pk). Number of input channels: 2. Input connectors: 2.4 mm (male). Input crosstalk: < -70 dB. Nominal input impedance: 50 ohm. Programmable dc Offset: ± 320 mV. Pulse generator (modulator out) Repetition frequency: 52.9 Hz - 5 MHz. Repetition period: 6.553 ms - 200 ns. Pulse width: 6.552 ms - 100 ns. The pulse generator is phase locked to the 10 MHz reference. Pulse width and repetition period are variable in 100 ns steps. Inaccuracies in the pulse widths are dominated by the transitions times (< 5 ns).



 

Standard Calibration $765.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 70820A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your Keysight (Agilent) 70820A REPAIR and/or Keysight (Agilent) 70820A Microwave Transition Analyzer, MMS CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: