A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 70845A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pattern Generator?
Shop for Comparable Products on our
 used Pattern Generator page

 
   Keysight (Agilent) 70845A   Description / Specification:    
Keysight (Agilent) 70845A Pattern Generator, MMS

HP 70845A pattern generator module for Modular Measurement System (MMS). Occupies 4/8 module slot and has seven I/O ports, six on the front panel and one on the rear. Operating Frequency Range: 50 Mbit/s to 1 Gbit/s. Patterns: PRBS Test Patterns: 2^23-1, polynomial D^23 + D^18 + 1 = 0, inverted; 2^15-1, polynomial D^15 + D^14 + 1 = 0, inverted; 2^10-1, polynomial D^10 + D^7 + 1 = 0, inverted & 2^7-1, polynomial D^7 + D^6 + 1 = 0, inverted. Zero Substitution/Variable Mark Density Test Patterns. Word Test Patterns. Alternating Word Test Patterns. Data Output Inhibit. Error Add. Data Polarity. Clock Input: Waveform: Sinewave from the HP 70322A or 70320A signal generators. Amplitude Range: ± 4 dBm. Return loss: Over operating frequency range: > 10 dB typical. Impedance: 50 ohm nominal. Interface: ac coupled. Connector: N-type female. Data and Data Outputs: Format: NRZ. Levels: Selectable amplitude and offset or nominal ECL, into 50 ohm to 0 V or 50 ohm to -2 V. Amplitude Range: 0.25 to 2 V p-p nominal. Amplitude Resolution: 10 mV nominal. ECL High level: -0.90 V, nominal. ECL Low level: -1.75 V nominal. Delay: Data delay variation vs clock output transitions: Range: ± 1 ns nominal, Resolution: 5 ps nominal. Jitter: Specified for 2^23-1 PRBS, 2 V p-p output amplitude, 0 V high level and measured relative to clock/32 trigger pulse. Clock and Clock Outputs: Amplitude: Range: 0.5 to 2 V p-p nominal, Resolution: 10 mV nominal. Transition Times: 10% to 90% at 25°C (typical). 1GHz, < 300 ps



 

Standard Calibration $935.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 70845A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
Optical power referenced to 1 millimatt

Optical Time Domain Reflectometer (OTDR)
Optical Time Domain Reflectometer (OTDR) is a device for characterizing a fiber wherein an optical pulse is transmitted through the fiber and the resulting backscatter and reflections to the input are measured as a function of time. Useful in estimating attenuation coefficient as a function of distance and identifying defects and other localized losses.

Synchronous Transport Module (STM)
STM-1 (Synchronous Transport Module level-1) is the SDH ITU-T fiber optic network transmission standard. It has a bit rate of 155.52 Mbit/s. Other levels are STM-4, STM-16 and STM-64.


Please contact us for your Keysight (Agilent) 70845A CALIBRATION and/or Keysight (Agilent) 70845A Pattern Generator, MMS REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: