Keysight (Agilent) 70902A REPAIR and Keysight (Agilent) 70902A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 70902A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 70902A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Spectrum Analyzer Component?
Shop for Comparable Products on our
 used Spectrum Analyzer Component page

 
   Keysight (Agilent) 70902A   Description / Specification:    
Keysight (Agilent) 70902A 3 MHz IF Section, MMS

The HP 70902A intermediate frequency (IF) section provides signal processing elements required for the spectrum analyzers, lightwave signal analyzers, and the GSM testers. It 1/8-width module for 70000 Modular Measurement System (MMS). The HP 70902A provides narrow resolution bandwidths, from 10 Hz to 300 kHz. Maximize measurement speed using 10% incremental bandwidths. Wider bandwidths offer the most speed, whereas narrow bandwidths offer more resolution and sensitivity. The 10% incremental bandwidth steps offer you the best choice of bandwidth sizes. The bandwidths can also be changed in a 1, 3, 10 sequence. Calibrated logging amplifiers provide superb amplitude accuracy for the analyzers. Four detection modes are available to properly display a variety of signals. Auxiliary video output: BNC (f), 0-1 V, 1 kohm (nominal), front panel. 3 MHz IF output (linear): BNC (f), 50 ohm, 1.5:1 VSWR (nominal), front panel. Output power: -15 dBm nominal with -10 dBm RF input, 0 dB attn and -10 dBm reference level. Limited IF output: 5MB (m) , ± 0.5 Vp-p (nominal), rear panel.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 70902A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your Keysight (Agilent) 70902A REPAIR and/or Keysight (Agilent) 70902A 3 MHz IF Section, MMS CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: