Keysight (Agilent) 70950A REPAIR and Keysight (Agilent) 70950A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 70950A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 70950A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   Keysight (Agilent) 70950A   Description / Specification:    
Keysight (Agilent) 70950A 600 to 1700 nm Optical Spectrum Analyzer Module, MMS

The HP 70950A is a 1700 nm Optical Spectrum Analyzer Module for 70000 Modular Measurement System (MMS). It is a 1/2 width module with FC/PC connectors standard. Sensitivity is -80 dBm and dynamic range is 60 dB 1 nm away from the signal. The resolution is 0.1 to 10 nm in a 1,2,5 sequence. The input connector system has a wide choice of adapter options. It offers three advanced functions to measure and characterize LED, DFB, or Fabry-Perot lasers. Specifications. Wavelength Range: 600 to 1700 nm. Wavelength Tuning repeatability: ±0.005 nm. Wavelength Span Range: 0.2 nm to full range. Wavelength Absolute Accuracy: ±1 nm. Maximum Sensitivity (1100-1600 nm): –90 dBm.Sweep Time sensitivity in auto, full span: < 0.5 seconds. Input Power, 1 dB compression level within resolution: =10 dBm. Dynamic Range: -50 dB at = ± 1 nm(600 to 1700 nm), -55 dB at = ± 0.5 nm(1250 to 1600 nm). Resolution: 0.08 nm, 0.1 nm, 10 nm (in a 1,2,5 sequence). Options. 001, Programmable Current Source. 002, Built-in White Light Source. 010, Delete FC/PC Interface. 051, EDFA Test Personality. 101, Enhanced Polarization Sensitivity.



Looking for a replacement? Try the  DEVISER AE8600

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 70950A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Isolation
The extent to which optical power from one signal path is prevented from reaching another signal path.

Polarization Extinction Ratio
Polarization Extinction Ratio is the ratio of optical power in the slow axis of the polarization maintaining fiber to optical power in the fast axis within a specified wavelength range.

Sidemode Suppression Ratio
Sidemode Suppression Ratio is the ratio of average signal power to the optical power of the highest sidemode within a distance from 0.1 to 6 GHz to the signal’s optical frequency, expressed in dB.

Wavelength Stability
Wavelength Stability is the change of wavelength during given time span, expressed as ± half the span between the maximum and the minimum of all actual wavelengths.


Please contact us for your Keysight (Agilent) 70950A REPAIR and/or Keysight (Agilent) 70950A 600 to 1700 nm Optical Spectrum Analyzer Module, MMS CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: